https://scholars.lib.ntu.edu.tw/handle/123456789/181266
標題: | On-Line Concentration of Microheterogeneous Proteins by Capillary Electrophoresis Using SDS and PEO as Additives | 作者: | Huang, Yu-Fen Hsieh, Ming-Mu Tseng, Wei-Lung Chang, Huan-Tsung |
關鍵字: | Capillary electrophoresis; On-line concentration; Poly(ethylene oxide); Red blood cell lysate; Sodium dodecyl sulfate; Urine | 公開日期: | 2006 | 卷: | 5 | 期: | 2 | 起(迄)頁: | 429-436 | 來源出版物: | Journal of Proteome Research | 摘要: | In this paper, we describe a method for analyzing large-volume protein samples using capillary electrophoresis in conjunction with laser-induced fluorescence detection (CE-LIF). To improve the stacking and separation efficiencies of proteins, we added either 0.01% sodium dodecyl sulfate (SDS) or 0.01% polyethylene oxide) (PEO) to the Tris-borate solutions (pH 10.0) used to prepare the protein samples. After injection of the large-volume samples (ca. 1.0 μL, 0.1 μM), the proteins migrate against the electroosmotic flow (EOF) and enter the PEO zone; this process causes them to slow and stack at the boundary between the PEO and sample zones. As a result, the limits of detection (LODs) at a signal-to-noise (S/N) of 3 for most proteins are sub-nM to several nM. For instance, the LOD (S/N = 3) for α-lactalbumin is 0.48 nM, which is an 84-fold sensitivity enhancement over the traditional method. By applying a short plug of 0.2% SDS prior to sample injection, a greater number of peaks, representing the microheterogeneity of the proteins, were resolved and the stacking efficiency of the proteins increased slightly. This method allowed us to detect 12 peaks when injecting a large volume of sample containing six model proteins (0.1 μM). We also analyzed the microheterogeneities of the proteins by using CE with UV-Vis absorption detection when injecting a large volume of sample containing six model proteins (1.0 μM) in the presence of a 1.0% SDS plug. The practical method is validated by the detection of human serum albumin in a urine sample, obtained from a healthy female, without sample pretreatment; its concentration was 0.18 μM. We further demonstrate the capability of this method to detect low amounts of proteins through the detection of 45 nM hemoglobin after injecting ca. 1.0 μL of ultradilute lysed red blood cells. The experimental results indicate that our proposed method has great potential for use in diagnosis and proteomics applications. ? 2006 American Chemical Society. |
URI: | http://ntur.lib.ntu.edu.tw//handle/246246/165250 http://ntur.lib.ntu.edu.tw/bitstream/246246/165250/1/71.pdf |
DOI: | 10.1021/pr050298y | SDG/關鍵字: | alpha lactalbumin; boric acid; dodecyl sulfate sodium; human serum albumin; macrogol; analytic method; article; capillary electrophoresis; controlled study; electroosmosis; fluorescence; human; human cell; light absorption; nonhuman; priority journal; protein analysis; proteomics; signal noise ratio; Electrophoresis, Capillary; Erythrocytes; Female; Fluorometry; Humans; Lasers; Polyethylene Glycols; Sodium Dodecyl Sulfate; Urine |
顯示於: | 化學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。