標題: | Diagnostic power of optic disc morphology, peripapillary retinal nerve fiber layer thickness, and macular inner retinal layer thickness in glaucoma diagnosis with fourier-domain optical coherence tomography | 作者: | JEHN-YU HUANG Pekmezci, Melike Mesiwala, Nisreen Kao, Andrew Lin, Shan |
關鍵字: | Fourier-domain optical coherent tomography; macular inner retinal layer; Optic disc; peripapillary retinal nerve fiber | 公開日期: | 2011 | 卷: | 20 | 期: | 2 | 起(迄)頁: | 87-94 | 來源出版物: | Journal of Glaucoma | 摘要: | Purpose: To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Methods: Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ?80%) was presented as the partial area under the ROC curve (partial AROC). Results: The individual OCT parameter with the largest AROC and partial AROC in the high specificity (?80%) range were cup/disc vertical ratio (AROC=0.854 and partial AROC=0.142) for the optic disc parameters, average thickness (AROC=0.919 and partial AROC=0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC=0.871 and partial AROC=0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC=0.970 and partial AROC=0.172). CONCLUSIONS: Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma. Copyright ? 2011 by Lippincott Williams & Wilkins. |
URI: | http://www.scopus.com/inward/record.url?eid=2-s2.0-79951675535&partnerID=MN8TOARS http://scholars.lib.ntu.edu.tw/handle/123456789/361494 |
DOI: | 10.1097/IJG.0b013e3181d787b6 | SDG/關鍵字: | adult; article; female; glaucoma; human; major clinical study; male; optic disk; optical coherence tomography; patient assessment; priority journal; retina; Cross-Sectional Studies; Female; Fourier Analysis; Glaucoma; Humans; Intraocular Pressure; Macula Lutea; Male; Middle Aged; Nerve Fibers; Optic Disk; Optic Nerve Diseases; Reproducibility of Results; Retinal Ganglion Cells; ROC Curve; Sensitivity and Specificity; Tomography, Optical Coherence; Visual Field Tests; Visual Fields |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。