https://scholars.lib.ntu.edu.tw/handle/123456789/368693
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Mesiwala, Nisreen K. | en_US |
dc.contributor.author | Pekmezci, Melike | en_US |
dc.contributor.author | JEHN-YU HUANG | en_US |
dc.contributor.author | Porco, Travis C. | en_US |
dc.contributor.author | Lin, Shan C. | en_US |
dc.creator | Mesiwala, N.K.;Pekmezci, M.;Huang, J.-Y.;Porco, T.C.;Lin, S.C. | - |
dc.date.accessioned | 2018-09-10T09:15:00Z | - |
dc.date.available | 2018-09-10T09:15:00Z | - |
dc.date.issued | 2012 | - |
dc.identifier.uri | http://www.scopus.com/inward/record.url?eid=2-s2.0-84867234266&partnerID=MN8TOARS | - |
dc.identifier.uri | http://scholars.lib.ntu.edu.tw/handle/123456789/368693 | - |
dc.description.abstract | PURPOSE: To compare optic disc measurements between the new Fourier-domain optical coherence tomography (RTVue-100) and the confocal scanning laser ophthalmoscopy (Heidelberg retinal tomography, HRT-II) in clinical practice. METHODS: Patients seen from the glaucoma service of an academic department of ophthalmology between August 2008 to August 2009 with good-quality RTVue-100 and HRT-II images within 6 months of each other were included (363 patients were included, 1 eye from each patient). The rim of the optic disc was drawn automatically by RTVue-100 and manually by a single experienced observer for HRT-II. Optic disc measurements from both imaging devices were compared using Bland-Altman plots and the Student t test to assess agreement. The main outcome measure was the agreement in optic disc parameters between the two imaging devices. RESULTS: Bland-Altman plots indicate significant differences between the RTVue-100 and HRT-II for all optic nerve parameters. The mean HRT-II values were consistently larger than RTVue-100 values for optic disc area and rim area. The RTVue-100 values were larger for the cup area, cup-to-disc area ratio, and vertical and horizontal cup-to-disc ratio. The Student t test showed P<0.001 for averages of all measurements between the two devices. CONCLUSIONS: We conclude that the disc parameters from these two imaging devices are not interchangeable. Copyright ? 2012 by Lippincott Williams & Wilkins. | en_US |
dc.language | en | en |
dc.relation.ispartof | Journal of Glaucoma | en_US |
dc.source | AH | - |
dc.subject | confocal scanning laser ophthalmoscopy; Fourier-domain optical coherence tomography; optic disc mergins; optic nerve head parameters; optical coherence tomography | en_US |
dc.subject.classification | [SDGs]SDG3 | - |
dc.subject.other | adult; article; cataract; comparative study; confocal scanning laser ophthalmoscope; cornea thickness; eye refraction; female; glaucoma; human; image quality; intraocular pressure; major clinical study; male; ophthalmological equipment; optic disk; optical coherence tomography; phakic intraocular lens; priority journal; pseudophakia; scanning laser ophthalmoscopy; visual acuity; visual system examination; visual system parameters; Diagnostic Techniques, Ophthalmological; Female; Fourier Analysis; Glaucoma; Humans; Male; Middle Aged; Ocular Hypertension; Ophthalmoscopes; Optic Disk; Optic Nerve Diseases; Reproducibility of Results; Tomography, Optical Coherence | - |
dc.title | Comparison of optic disc parameters measured by RTVue-100 FDOCT versus HRT-II | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1097/IJG.0b013e3182253e58 | - |
dc.relation.pages | 516-522 | en_US |
dc.relation.journalvolume | 21 | en_US |
dc.relation.journalissue | 8 | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | journal article | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
crisitem.author.dept | Ophthalmology | - |
crisitem.author.dept | Ophthalmology-NTUH | - |
crisitem.author.dept | Division of Glaucoma | - |
crisitem.author.orcid | 0000-0002-4452-4557 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | Ophthalmology-NTUH | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。