https://scholars.lib.ntu.edu.tw/handle/123456789/431103
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | TSUNG-CHIEN LU | en_US |
dc.contributor.author | Chang, Yao Ting | en_US |
dc.contributor.author | Ho, Te Wei | en_US |
dc.contributor.author | Chen, Yi | en_US |
dc.contributor.author | Lee, Yi Ting | en_US |
dc.contributor.author | Wang, Yu Siang | en_US |
dc.contributor.author | YEN-PIN CHEN | en_US |
dc.contributor.author | CHU-LIN TSAI | en_US |
dc.contributor.author | MATTHEW HUEI-MING MA | en_US |
dc.contributor.author | CHENG-CHUNG FANG | en_US |
dc.contributor.author | FEI-PEI LAI | en_US |
dc.contributor.author | Meischke, Hendrika W. | en_US |
dc.creator | FEI-PEI LAI;Turner, Anne M.;Meischke, Hendrika W.;CHENG-CHUNG FANG;MATTHEW HUEI-MING MA;CHU-LIN TSAI;Chen, Yen Pin;Wang, Yu Siang;Lee, Yi Ting;Chen, Yi;Ho, Te Wei;Chang, Yao Ting;TSUNG-CHIEN LU | - |
dc.date.accessioned | 2019-11-12T02:28:42Z | - |
dc.date.available | 2019-11-12T02:28:42Z | - |
dc.date.issued | 2019-07-01 | - |
dc.identifier.issn | 03009572 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/431103 | - |
dc.description.abstract | © 2019 Elsevier B.V. Aim: Cardiopulmonary resuscitation (CPR) quality affects survival after cardiac arrest. We aimed to investigate if a smartwatch with real-time feedback can improve CPR quality by healthcare professionals. Methods: An app providing real-time audiovisual feedback was developed for a smartwatch. Emergency Department (ED) professionals were recruited and randomly allocated to either the intervention group wearing a smartwatch with the preinstalled app, or to a control group. All participants were asked to perform a two-minute CPR on a manikin at a 30:2 compression-ventilation ratio. Primary outcomes were the mean CCR and CCD measured on the manikin. A secondary outcome was the percentage of chest compressions meeting both the guideline-recommended rate (100–120 min −1 ) and depth (50–60 mm) of high-quality CPR during a 2-min period. Differences between groups were evaluated with t-test, Chi-Square test, or Mann–Whitney U test depending on the distribution. Results: Eighty participants were recruited. 40 people were assigned to the intervention and 40 to the control group. The compression rates (mean ± SD, min −1 ) were significantly faster (but above the guideline recommendation, P < 0.001) in the control (129.1 ± 14.9) than in the intervention group (112.0 ± 3.5). The compression depths (mean ± SD, mm) were significantly deeper (P < 0.001) in the intervention (50.9 ± 6.6) than in the control group (39.0 ± 8.7). The percentage (%) of high-quality CPR was significantly higher (P < 0.001) in the intervention (median 39.4, IQR 27.1–50.1) than in the control group (median 0.0, IQR 0.0−0.0). Conclusion: Without real-time feedback, chest compressions tend to be too fast and too shallow. CPR quality can be improved with the assistance of a smartwatch providing real-time feedback. | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER IRELAND LTD | en_US |
dc.relation.ispartof | Resuscitation | en_US |
dc.subject | Cardiac arrest | Cardiopulmonary resuscitation | Chest compression | Feedback device | Smartwatch | Wearable device | en_US |
dc.subject | Cardiac arrest; Cardiopulmonary resuscitation; Chest compression; Feedback device; Smartwatch; Wearable device | - |
dc.subject.classification | [SDGs]SDG3 | - |
dc.subject.other | adult; Article; auditory feedback; clinical evaluation; controlled study; emergency nurse practitioner; emergency physician; emergency ward; female; health care delivery; health care personnel; health care quality; human; intervention study; male; mobile application; outcome assessment; priority journal; randomized controlled trial; registered nurse; resuscitation; simulation training; visual feedback; electronic device; feedback system; health care personnel; heart massage; manikin; mobile application; resuscitation; Adult; Cardiopulmonary Resuscitation; Feedback; Female; Health Personnel; Heart Massage; Humans; Male; Manikins; Mobile Applications; Wearable Electronic Devices | - |
dc.title | Using a smartwatch with real-time feedback improves the delivery of high-quality cardiopulmonary resuscitation by healthcare professionals | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1016/j.resuscitation.2019.04.050 | - |
dc.identifier.pmid | 31078650 | - |
dc.identifier.scopus | 2-s2.0-85065717251 | - |
dc.identifier.isi | WOS:000472733000004 | - |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/85065717251 | - |
dc.relation.pages | 16 | en_US |
dc.relation.journalvolume | 140 | en_US |
dc.relation.pageend | 22 | en_US |
item.cerifentitytype | Publications | - |
item.languageiso639-1 | en | - |
item.openairetype | journal article | - |
item.fulltext | no fulltext | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
crisitem.author.dept | Emergency Medicine | - |
crisitem.author.dept | Emergency Medicine-NTUH | - |
crisitem.author.dept | Emergency Medicine | - |
crisitem.author.dept | Emergency Medicine-NTUH | - |
crisitem.author.dept | Emergency Medicine | - |
crisitem.author.dept | Emergency Medicine-NTUH | - |
crisitem.author.dept | Emergency Medicine | - |
crisitem.author.dept | Emergency Medicine-NTUH | - |
crisitem.author.dept | National Taiwan University Hospital Yun-Lin Branch | - |
crisitem.author.dept | Emergency Medicine | - |
crisitem.author.dept | Emergency Medicine-NTUH | - |
crisitem.author.dept | Biomedical Electronics and Bioinformatics | - |
crisitem.author.dept | Computer Science and Information Engineering | - |
crisitem.author.dept | Electrical Engineering | - |
crisitem.author.orcid | 0000-0003-2729-7142 | - |
crisitem.author.orcid | 0000-0002-2473-0847 | - |
crisitem.author.orcid | 0000-0003-4639-1513 | - |
crisitem.author.orcid | 0000-0002-4388-9984 | - |
crisitem.author.orcid | 0000-0001-5386-6674 | - |
crisitem.author.orcid | 0000-0003-0179-7325 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。