https://scholars.lib.ntu.edu.tw/handle/123456789/469778
標題: | QTcheterogeneity in rest magnetocardiography is sensitive to detect coronary artery disease: In comparison with stress myocardial perfusion imaging | 作者: | YEN-WEN WU Lin, Lung-Chun Tseng W.-K. YEN BIN LIU HSIEN-LI KAO MAO-SHIN LIN HUI-CHUN HUANG Wang S.-Y. Horng H.-E. Yang H.-C. CHAU-CHUNG WU |
公開日期: | 2014 | 出版社: | Republic of China Society of Cardiology | 卷: | 30 | 期: | 5 | 起(迄)頁: | 445-454 | 來源出版物: | Acta Cardiologica Sinica | 摘要: | Background: Stress nuclear myocardial perfusion imaging (MPI) is an established method for diagnosis and prognosis of coronary artery disease (CAD). However, radiation exposure limits its clinical application. Magnetocardiography (MCG) has been proposed as a non-contact, rapid and non-radiation technique with high reproducibility. The aim of the study was to evaluate the diagnostic efficacy of rest MCG in CAD comparing to stress MPI.Methods: We prospectively enrolled 55 patients with suspected CAD (64 ± 10 years) who were scheduled for coronary angiography (CA).MCG, stress 201Tl MPI and CAwere performed within 3 months. The spatial distribution maps of QTcinterval (21 × 21 in resolution) were derived from a 64-channel MCG system (KRISS, Korea). T-wave propagation mapping, repolarization heterogeneity index with QTcdispersion and smoothness index of QTc(SI-QTc) were analyzed, and the diagnostic criteria for CAD were developed based on the receiver operating characteristic (ROC) curve analysis.Results: Patients with significant CAD (? 70% luminal stenosis, n = 36) had higher QTcdispersion and SI-QTcthan controls (both p < 0.05). The diagnostic sensitivity and specificity were 0.8330, 0.6842 for QTcdispersion ? 79 ms; 0.7778, 0.6842 for SI-QTc? 9.1ms; and 0.8611, 0.6842 for combination. There was no difference of area under ROC curve by using criteria of QTcdispersion ? 79 ms, SI-QTc? 9.1 ms or combination (0.7588, 0.7310, 0.7727, p = NS), and non-inferior to stress MPI (p = NS).Conclusions: The QTcheterogeneity parameters of rest MCG yield a good sensitivity and acceptable specificity for detection of CAD, and may provide an alternative to stress MPI without stress and radiation. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84907272873&partnerID=40&md5=f65c19a4cc12879a5473b3055f024f00 https://scholars.lib.ntu.edu.tw/handle/123456789/469778 |
ISSN: | 1011-6842 | SDG/關鍵字: | thallium 201; adult; angiocardiography; angiography device; Article; controlled study; coronary artery disease; diagnostic accuracy; diagnostic test accuracy study; female; human; intermethod comparison; magnetocardiograph; magnetocardiography; major clinical study; male; myocardial perfusion imaging; prospective study; QT dispersion; rest magnetocardiography; sensitivity and specificity; stress myocardial perfusion imaging; ultrasound transducer |
顯示於: | 醫學教育暨生醫倫理學科所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。