https://scholars.lib.ntu.edu.tw/handle/123456789/481434
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Xia J. | en_US |
dc.contributor.author | Li Q. | en_US |
dc.contributor.author | Liu H.-L. | en_US |
dc.contributor.author | WEN-SHIANG CHEN | en_US |
dc.contributor.author | Tsui P.-H. | en_US |
dc.contributor.author | HAO-LI LIU | en_US |
dc.contributor.author | JJ Xia | en_US |
dc.contributor.author | Q Li | en_US |
dc.contributor.author | HL Liu | en_US |
dc.contributor.author | PH Tsui | en_US |
dc.creator | Xia J.;Li Q.;Liu H.-L.;Wen-Shiang Chen;Tsui P.-H. | - |
dc.date.accessioned | 2020-03-30T13:03:38Z | - |
dc.date.available | 2020-03-30T13:03:38Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1748-670X | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84887482159&doi=10.1155%2f2013%2f682827&partnerID=40&md5=6b30f8f8db89c34d9ed88c98b52cf32f | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/481434 | - |
dc.description.abstract | Previous studies developed ultrasound temperature-imaging methods based on changes in backscattered energy (CBE) to monitor variations in temperature during hyperthermia. In conventional CBE imaging, tracking and compensation of the echo shift due to temperature increase need to be done. Moreover, the CBE image does not enable visualization of the temperature distribution in tissues during nonuniform heating, which limits its clinical application in guidance of tissue ablation treatment. In this study, we investigated a CBE imaging method based on the sliding window technique and the polynomial approximation of the integrated CBE (ICB E pa image) to overcome the difficulties of conventional CBE imaging. We conducted experiments with tissue samples of pork tenderloin ablated by microwave irradiation to validate the feasibility of the proposed method. During ablation, the raw backscattered signals were acquired using an ultrasound scanner for B-mode and ICB E pa imaging. The experimental results showed that the proposed ICB E pa image can visualize the temperature distribution in a tissue with a very good contrast. Moreover, tracking and compensation of the echo shift were not necessary when using the ICB E pa image to visualize the temperature profile. The experimental findings suggested that the ICB E pa image, a new CBE imaging method, has a great potential in CBE-based imaging of hyperthermia and other thermal therapies. © 2013 Jingjing Xia et al. | - |
dc.publisher | Hindawi Publishing Corporation | - |
dc.relation.ispartof | Computational and Mathematical Methods in Medicine | - |
dc.subject.other | Ablation; Backscattering; Histology; Microwave irradiation; Polynomial approximation; Temperature distribution; Tissue; Ultrasonic applications; Visualization; Backscattered signal; Changes in backscattered energies; Clinical application; Sliding window techniques; Temperature imaging; Temperature increase; Temperature profiles; Ultrasound scanners; Tissue engineering; article; contrast to noise ratio; energy; image processing; microwave irradiation; microwave therapy; temperature; time; ultrasound; ultrasound scanner; animal; biological model; body temperature; diagnostic imaging; human; hyperthermic therapy; microwave radiation; physiology; radiation scattering; statistics; swine; thermometry; ultrasound; body temperature; physiology; statistics and numerical data; Animals; Body Temperature; Diagnostic Imaging; Humans; Hyperthermia, Induced; Microwaves; Models, Biological; Scattering, Radiation; Sus scrofa; Thermometry; Ultrasonics; Animals; Body Temperature; Diagnostic Imaging; Humans; Hyperthermia, Induced; Microwaves; Models, Biological; Scattering, Radiation; Sus scrofa; Thermometry; Ultrasonics | - |
dc.title | An approach for the visualization of temperature distribution in tissues according to changes in ultrasonic backscattered energy | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1155/2013/682827 | - |
dc.identifier.pmid | 24260041 | - |
dc.identifier.scopus | 2-s2.0-84887482159 | - |
dc.relation.pages | 682827 | - |
dc.relation.journalvolume | 2013 | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | journal article | - |
item.grantfulltext | none | - |
crisitem.author.dept | Physical Medicine and Rehabilitation | - |
crisitem.author.dept | Physical Medicine and Rehabilitation-NTUH | - |
crisitem.author.dept | Electrical Engineering | - |
crisitem.author.orcid | 0000-0003-1488-5164 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。