https://scholars.lib.ntu.edu.tw/handle/123456789/483903
標題: | Psychometric comparisons of 4 measures for assessing upper-extremity function in people with stroke | 作者: | Lin J.-H. Hsu M.-J. Sheu C.-F. Wu T.-S. Lin R.-T. Chen C.-H. CHING-LIN HSIEH |
公開日期: | 2009 | 卷: | 89 | 期: | 8 | 起(迄)頁: | 840-850 | 來源出版物: | Physical Therapy | 摘要: | Background. Functional limitation of the upper extremities is common in patients with stroke. An upper-extremity measure with sound psychometric properties is indispensable for clinical and research use. Objective. The purpose of this study was to compare the psychometric properties of 4 clinical measures for assessing upper-extremity motor function in people with stroke: the upper-extremity subscale of the Fugl-Meyer Motor Test (UE-FM), the upper-extremity subscale of the Stroke Rehabilitation Assessment of Movement, the Action Research Arm Test (ARAT), and the Wolf Motor Function Test. Design. This was a prospective, longitudinal study. Methods. Fifty-three people with stroke were evaluated with the 4 measures at 4 time points (14, 30, 90, and 180 days after stroke). Thirty-live participants completed all of the assessments. The ceiling and floor effects, validity (concurrent validity and predictive validity), and responsiveness of each measure were examined. Interrater reliability and test-retest reliability also were examined. Results. All measures, except for the UE-FM, had significant floor effects or ceiling effects at one or more time points. The Spearman ρ correlation coefficient for each pair of the 4 measures was ?.81, indicating high concurrent validity. The predictive validity of the 4 measures was satisfactory (Spearman ρ, ?.51). The responsiveness of the 4 measures at 14 to 180 days after stroke was moderate (.52 ? effect size ? .79). The 4 measures had good interrater reliability (intraclass correlation coefficient [ICC], ?.92) and test-retest reliability (ICC, ?.97). Only the minimal detectable changes of the UE-FM (8% of the highest possible score) and the ARAT (6%) were satisfactory. Limitations. The sample size was too small to conduct data analysis according to type or severity of stroke. In addition, the timed component of the Wolf Motor Function Test was not used in this study. Conclusions. All 4 measures showed sufficient validity, responsiveness, and reliability in participants with stroke. The UE-FM for assessing impairment and the ARAT for assessing disability had satisfactory minimal detectable changes, supporting their utility in clinical settings. ? 2009 American Physical Therapy Association. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-68249103598&doi=10.2522%2fptj.20080285&partnerID=40&md5=cf090573157de99359572ebcda1bf5ff https://scholars.lib.ntu.edu.tw/handle/123456789/483903 |
ISSN: | 0031-9023 | DOI: | 10.2522/ptj.20080285 | SDG/關鍵字: | Action Research Arm test; adult; arm movement; article; clinical article; clinical assessment; concurrent validity; diagnostic accuracy; effect size; female; Fugl Meyer Motor Test; human; intermethod comparison; interrater reliability; longitudinal study; male; motor performance; outcome assessment; prospective study; psychometry; scoring system; stroke; Stroke Rehabilitation Assessment of Movement; test retest reliability; wolf motor function test; Aged; Disability Evaluation; Female; Hand Strength; Health Status Indicators; Humans; Male; Middle Aged; Muscle Weakness; Prospective Studies; Psychometrics; Recovery of Function; Stroke; Task Performance and Analysis; Upper Extremity |
顯示於: | 職能治療學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。