標題: | Skin Dose Impact from Vacuum Immobilization Device and Carbon Fiber Couch in Intensity Modulated Radiation Therapy for Prostate Cancer | 作者: | Lee K.-W. Wu J.-K. Jeng S.-C. Hsueh Liu Y.-W. CHIA-HSIEN CHENG |
關鍵字: | Couch; Intensity-modulated radiation therapy; Prostate cancer; Skin; Vacuum immobilization device | 公開日期: | 2009 | 卷: | 34 | 期: | 3 | 起(迄)頁: | 228-232 | 來源出版物: | Medical Dosimetry | 摘要: | To investigate the unexpected skin dose increase from intensity-modulated radiation therapy (IMRT) on vacuum cushions and carbon-fiber couches and then to modify the dosimetric plan accordingly. Eleven prostate cancer patients undergoing IMRT were treated in prone position with a vacuum cushion. Two under-couch beams scattered the radiation from the vacuum cushion and carbon-fiber couch. The IMRT plans with both devices contoured were compared with the plans not contouring them. The skin doses were measured using thermoluminescent dosimeters (TLDs) placed on the inguinal regions in a single IMRT fraction. Tissue equivalent thickness was transformed for both devices with the relative densities. The TLD-measured skin doses (59.5 ± 9.5 cGy and 55.6 ± 5.9 cGy at left and right inguinal regions, respectively) were significantly higher than the calculated doses (28.7 ± 4.7 cGy; p = 2.2 × 10-5 and 26.2 ± 4.3 cGy; p = 1.5 × 10-5) not contouring the vacuum cushion and carbon-fiber couch. The calculated skin doses with both devices contoured (59.1 ± 8.8 cGy and 55.5 ± 5.7 cGy) were similar to the TLD-measured doses. In addition, the calculated skin doses using the vacuum cushion and a converted thickness of the simulator couch were no different from the TLD-measured doses. The recalculated doses of rectum and bladder did not change significantly. The dose that covered 95% of target volume was less than the prescribed dose in 4 of 11 patients, and this problem was solved after re-optimization applying the corrected contours. The vacuum cushion and carbon-fiber couch contributed to increased skin doses. The tissue-equivalent-thickness method served as an effective way to correct the dose variations. ? 2009 American Association of Medical Dosimetrists. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-67651214053&doi=10.1016%2fj.meddos.2008.10.001&partnerID=40&md5=eae1490fc79e0ccd43ccc5d79d2426bb https://scholars.lib.ntu.edu.tw/handle/123456789/485704 |
ISSN: | 0958-3947 | DOI: | 10.1016/j.meddos.2008.10.001 | SDG/關鍵字: | carbon fiber; adult; aged; article; body posture; cancer patient; clinical article; dosimetry; external beam radiotherapy; human; intensity modulated radiation therapy; photon therapy; priority journal; prostate cancer; radiation dose; radiation dose distribution; radiation shield; simulator; skin toxicity; thermoluminescence dosimeter; treatment planning; vacuum; vacuum immobilization device; Beds; Body Burden; Carbon; Equipment Design; Equipment Failure Analysis; Humans; Immobilization; Male; Organ Specificity; Prostatic Neoplasms; Radiometry; Radiotherapy Dosage; Radiotherapy, Conformal; Skin; Vacuum |
顯示於: | 腫瘤醫學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。