https://scholars.lib.ntu.edu.tw/handle/123456789/511367
標題: | Assessing hepatic fibrosis: comparing the intravoxel incoherent motion in MRI with acoustic radiation force impulse imaging in US | 作者: | CHIH-HORNG WU MING-CHIH HO YUNG-MING JENG PO-CHIN LIANG REY-HENG HU HONG-SHIEE LAI TIFFANY TING-FANG SHIH |
公開日期: | 2015 | 卷: | 25 | 期: | 12 | 起(迄)頁: | 3552-3559 | 來源出版物: | European Radiology | 摘要: | Objectives: This study compared the diagnostic performance of intravoxel incoherent motion (IVIM) in magnetic resonance imaging (MRI) and acoustic radiation force impulse imaging (ARFI) in ultrasound (US) for liver fibrosis (LF) evaluation. Methods: A total of 49 patients scheduled for liver surgery were recruited. LF in the non-tumorous liver parenchyma at the right lobe was estimated using a slow diffusion coefficient, fast diffusion coefficient (Dfast), perfusion fraction (f) of the IVIM parameters, the total apparent diffusion coefficient of conventional diffusion-weighted imaging and the shear wave velocity (Vs) of ARFI. LF was graded using the Metavir scoring system on histological examination. The Spearman rank correlation coefficient for correlation and analysis of variance was used for determining difference. The diagnostic performance was compared using receiver operating characteristic curve analysis. Results: LF exhibited significant correlation with the three parameters Dfast, f, and Vs (r = ?0.528, ?0.337, and 0.481, respectively, P < 0.05). The Dfast values in the F4 group were significantly lower than those in the F0, F1 and F2 groups. Dfast exhibited a non-inferior performance for diagnosing all fibrosis grades compared with that of Vs. Conclusions: Both IVIM and ARFI provide reliable estimations for the noninvasive assessment of LF. Key Points: ? Liver fibrosis can be diagnosed and graded using noninvasive imaging modalities. ? ARFI and IVIM can be incorporated into routine examinations. ? IVIM can differentiate liver cirrhosis from none to moderate liver fibrosis. ? The diagnostic performances of IVIM and ARFI are equal. ? 2015, European Society of Radiology. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/511367 | ISSN: | 0938-7994 | DOI: | 10.1007/s00330-015-3774-4 | SDG/關鍵字: | acoustic radiation force impulse imaging; adult; aged; Article; clinical article; controlled study; diagnostic accuracy; diagnostic test accuracy study; diffusion weighted imaging; female; hepatitis B; hepatitis C; human; human tissue; intravoxel incoherent motion; liver fibrosis; liver parenchyma; liver surgery; male; Metavir scoring system; nuclear magnetic resonance imaging; nuclear magnetic resonance scanner; predictive value; priority journal; prospective study; radiological parameters; real time ultrasound scanner; scoring system; sensitivity and specificity; shear wave velocity; ultrasound transducer; United States; very elderly; comparative study; echography; elastography; liver; liver cirrhosis; middle aged; pathology; receiver operating characteristic; reproducibility; young adult; Adult; Aged; Aged, 80 and over; Elasticity Imaging Techniques; Female; Humans; Liver; Liver Cirrhosis; Magnetic Resonance Imaging; Male; Middle Aged; Prospective Studies; Reproducibility of Results; ROC Curve; Young Adult |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。