https://scholars.lib.ntu.edu.tw/handle/123456789/515582
DC Field | Value | Language |
---|---|---|
dc.contributor.author | FON-YIH TSUANG | en_US |
dc.contributor.author | Chen, C.-H. | en_US |
dc.contributor.author | Kuo, Y.-J. | en_US |
dc.contributor.author | Tseng, W.-L. | en_US |
dc.contributor.author | Chen, Y.-S. | en_US |
dc.contributor.author | Lin, C.-J. | en_US |
dc.contributor.author | Liao, C.-J. | en_US |
dc.contributor.author | Lin, F.-H. | en_US |
dc.contributor.author | FENG-HUEI LIN | en_US |
dc.creator | Fon-Yih Tsuang;Chen C.-H.;Kuo Y.-J.;Tseng W.-L.;Chen Y.-S.;Lin C.-J.;Liao C.-J.;Lin F.-H.;Chiang C.-J. | - |
dc.date.accessioned | 2020-09-29T03:36:17Z | - |
dc.date.available | 2020-09-29T03:36:17Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1529-9430 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/515582 | - |
dc.description.abstract | Background Context Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions. Purpose This study aimed to demonstrate a method for percutaneous screws placement using only the anterior-posterior (AP) trajectory of intraoperative fluoroscopy. Study Design A technical report (a retrospective and prospective case series) was carried out. Patient Sample Patients who received posterior fixation with percutaneous pedicle screws for thoracolumbar degenerative disease or trauma comprised the patient sample. Method We retrospectively reviewed the charts of consecutive 670 patients who received 4,072 pedicle screws between December 2010 and August 2015. Another case series study was conducted prospectively in three additional hospitals, and 88 consecutive patients with 413 pedicle screws were enrolled from February 2014 to July 2016. The fluoroscopy shot number and radiation dose were recorded. In the prospective study, 78 patients with 371 screws received computed tomography at 3 months postoperatively to evaluate the fusion condition and screw positions. Results In the retrospective series, the placement of a percutaneous screw required 5.1 shots (2–14, standard deviation [SD]=2.366) of AP fluoroscopy. One screw was revised because of a medialwall breach of the pedicle. In the prospective series, 5.8 shots (2–16, SD=2.669) were required forone percutaneous pedicle screw placement. There were two screws with a Grade 1 breach (8.6%), both at the lateral wall of the pedicle, out of 23 screws placed at the thoracic spine at T9–T12. Forthe lumbar and sacral areas, there were 15 Grade 1 breaches (4.3%), 1 Grade 2 breach (0.3%), and 1 Grade 3 breach (0.3%). No revision surgery was necessary. Conclusion This method avoids lateral shots of fluoroscopy during screw placement and thus decreases the operation time and exposes surgeons to less radiation. At the same time, compared with the computer-navigated procedure, it is less facility-demanding, and provides satisfactory reliability and accuracy. ? 2017 The Authors | - |
dc.relation.ispartof | Spine Journal | - |
dc.subject.other | anterior posterior axis; Article; case study; computer assisted tomography; endoprosthesis fracture; fluoroscopy; human; intraoperative period; Kirschner wire; longitudinal study; lumbar spine; major clinical study; multicenter study; operation duration; pedicle screw; priority journal; prospective study; radiation dose; reoperation; retrospective study; sacrum; spinal cord atrophy; thoracic spine; thoracolumbar spine; adult; adverse device effect; aged; cohort analysis; computer assisted surgery; evaluation study; female; fluoroscopy; lumbar vertebra; male; middle aged; minimally invasive surgery; pedicle screw; postoperative complication; procedures; spine fusion; surgery; Adult; Aged; Cohort Studies; Female; Fluoroscopy; Humans; Lumbar Vertebrae; Male; Middle Aged; Minimally Invasive Surgical Procedures; Operative Time; Pedicle Screws; Postoperative Complications; Reoperation; Spinal Fusion; Surgery, Computer-Assisted | - |
dc.subject.other | [SDGs]SDG3 | - |
dc.title | Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder—a technical note and case series | en_US |
dc.type | journal article | - |
dc.identifier.doi | 10.1016/j.spinee.2017.06.022 | - |
dc.identifier.pmid | 28645672 | - |
dc.identifier.scopus | 2-s2.0-85025134557 | - |
dc.relation.pages | 1373-1380 | - |
dc.relation.journalvolume | 17 | - |
dc.relation.journalissue | 9 | - |
item.fulltext | no fulltext | - |
item.openairetype | journal article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
crisitem.author.dept | Surgery-NTUH | - |
crisitem.author.dept | Surgery | - |
crisitem.author.dept | Biomedical Engineering | - |
crisitem.author.orcid | 0000-0001-5797-1885 | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | College of Engineering | - |
Appears in Collections: | 醫學院附設醫院 (臺大醫院) |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.