標題: | The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera | 作者: | Lin W.-L. Wang S.-Y. Shiau Y.-C. YEN-WEN WU |
關鍵字: | Coronary artery disease; left ventricular mechanical dyssynchrony; phase analysis; single photon emission computed tomography | 公開日期: | 2020 | 卷: | 27 | 期: | 1 | 起(迄)頁: | 241-250 | 來源出版物: | Journal of Nuclear Cardiology | 摘要: | Background: Previous studies have demonstrated left ventricular mechanical dyssynchrony (LVMD) in patients with severe coronary artery disease (CAD) with ? 70% stenosis. The aim of this study was to evaluate the clinical usefulness of stress/rest LVMD in the diagnosis of CAD with ? 50% stenosis using dipyridamole thallium-201 (Tl-201) myocardial perfusion imaging (MPI) with a cadmium-zinc-telluride camera. Methods and Results: A total of 476 patients without known CAD who underwent dipyridamole Tl-201 MPI and coronary angiography within 6?months were retrospectively reviewed. LVMD parameters including phase standard deviation and phase histogram bandwidth, phase skewness and phase kurtosis, as well as myocardial perfusion and myocardial stunning were assessed in post-stress and rest MPI. Relationships between the presence of CAD on coronary angiography and single photon emission computerized tomography (SPECT) parameters were evaluated. The presence of perfusion abnormalities was the best diagnostic tool in detecting CAD. Although less left ventricular synchrony was observed post-stress in the CAD group compared to the non-CAD group, no significant dyssynchrony was noted. Conclusions: The addition of phase analysis to help diagnose CAD in Tl-201-gated SPECT with dipyridamole stress may have limited value in patients with CAD with ? 50% stenosis. ? 2018, American Society of Nuclear Cardiology. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/553647 | ISSN: | 1071-3581 | DOI: | 10.1007/s12350-018-1417-2 | SDG/關鍵字: | cadmium; chlormethine; dipyridamole tl 201; tellurium; zinc; cadmium; CdZnTe; dipyridamole; tellurium; thallium; Thallium-201; vasodilator agent; zinc; adult; Article; cardiac gated imaging; controlled study; coronary angiography; coronary artery disease; diagnostic accuracy; diagnostic test accuracy study; diagnostic value; female; heart catheterization; heart left ventricle ejection fraction; heart muscle perfusion; human; image analysis; major clinical study; male; medical record review; middle aged; myocardial perfusion imaging; priority journal; retrospective study; sensitivity and specificity; single photon emission computed tomography; stunned heart muscle; aged; coronary artery disease; diagnostic imaging; gated single photon emission computed tomography; heart ventricle function; pathophysiology; stunned heart muscle; Aged; Cadmium; Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography; Coronary Angiography; Coronary Artery Disease; Dipyridamole; Female; Humans; Male; Middle Aged; Myocardial Perfusion Imaging; Myocardial Stunning; Tellurium; Thallium Radioisotopes; Vasodilator Agents; Ventricular Function; Zinc |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。