https://scholars.lib.ntu.edu.tw/handle/123456789/573276
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Kuo C.-T | en_US |
dc.contributor.author | Wang J.-Y | en_US |
dc.contributor.author | Lu S.-R | en_US |
dc.contributor.author | Lai Y.-S | en_US |
dc.contributor.author | Chang H.-H | en_US |
dc.contributor.author | Hsieh J.-T | en_US |
dc.contributor.author | Wo A.M | en_US |
dc.contributor.author | Chen B.P.C | en_US |
dc.contributor.author | Lee H. | en_US |
dc.contributor.author | HSIN-YU LEE | en_US |
dc.creator | Kuo C.-T;Wang J.-Y;Lu S.-R;Lai Y.-S;Chang H.-H;Hsieh J.-T;Wo A.M;Chen B.P.C;Lee H. | - |
dc.date.accessioned | 2021-07-26T10:03:49Z | - |
dc.date.available | 2021-07-26T10:03:49Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079810509&partnerID=40&md5=465a6fc839c9e91bf2887b9ed9e400dc | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/573276 | - |
dc.description.abstract | A novel biomimic microwell array (bio-μ-array) sensor is developed to facilitate the prediction of in vivo efficacy, which has been demonstrated to be more accurate than conventional 96-well plate assays. This array sensor may provide a simple and cost-effective solution to meet the high-throughput requirement for personalized cancer medicine. Copyright ? (2018) by Chemical and Biological Microsystems Society. All rights reserved. | - |
dc.relation.ispartof | 22nd International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2018 | - |
dc.subject | Cost effectiveness; Diagnosis; Microchannels; 96-Well plate; Array sensors; Biomimic; Cost-effective solutions; Drug screening; High throughput; In-vitro; Micro wells; Personalized medicine | - |
dc.subject.classification | [SDGs]SDG3 | - |
dc.subject.other | Cost effectiveness; Diagnosis; Microchannels; 96-Well plate; Array sensors; Biomimic; Cost-effective solutions; Drug screening; High throughput; In-vitro; Micro wells; Personalized medicine | - |
dc.title | Biomimic microwell array sensors to identify effective chemotherapeutic combinations in vitro and in vivo | en_US |
dc.type | conference paper | en |
dc.identifier.scopus | 2-s2.0-85079810509 | - |
dc.relation.pages | 1927-1930 | - |
dc.relation.journalvolume | 4 | - |
item.fulltext | no fulltext | - |
item.openairetype | conference paper | - |
item.openairecristype | http://purl.org/coar/resource_type/c_5794 | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Biomedical Electronics and Bioinformatics | - |
crisitem.author.dept | Life Science | - |
crisitem.author.dept | Center for Biotechnology | - |
crisitem.author.dept | Electrical Engineering | - |
crisitem.author.orcid | 0000-0002-1477-0183 | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | College of Life Science | - |
crisitem.author.parentorg | Others: University-Level Research Centers | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
顯示於: | 生命科學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。