https://scholars.lib.ntu.edu.tw/handle/123456789/577166
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chen T.-Y | en_US |
dc.contributor.author | Kuo C.-C | en_US |
dc.contributor.author | Hung L.-W | en_US |
dc.contributor.author | Lee W.-C | en_US |
dc.contributor.author | Lo J.-H | en_US |
dc.contributor.author | Lu H.-L | en_US |
dc.contributor.author | Lu T.-W. | en_US |
dc.contributor.author | TUNG-WU LU | en_US |
dc.creator | Chen T.-Y;Kuo C.-C;Hung L.-W;Lee W.-C;Lo J.-H;Lu H.-L;Lu T.-W. | - |
dc.date.accessioned | 2021-08-05T02:42:05Z | - |
dc.date.available | 2021-08-05T02:42:05Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 20763417 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106660082&doi=10.3390%2fapp11104447&partnerID=40&md5=cf73c54f036251992e898bbbf58d0256 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/577166 | - |
dc.description.abstract | Background: Assessment of the sole morphology provides a clinically useful measure of the foot condition, but existing methods are mostly limited to two-dimensional or non-weight-bearing conditions. The current study aimed to assess the reliability of a novel method called Single-Image-Based Pin-Array Impression Reconstruction Method (SIBPAIR) implemented on a commercial foot assessment system, and the intra-rater, inter-rater and inter-session reliability of the SIBPAIR-based protocol for three-dimensional sole morphological measurements. Methods: The reliability of the SIBPAIR method, and the intra-rater, inter-rater, and inter-session reliability of the SIBPAIR-based protocol in measuring morphological parameters of the sole were assessed by repeated measurements of fifteen young healthy adults by two male physical therapists, in terms of intra-class correlation coefficients (ICC) and standard error of measurement (SEM). Results and Conclusions: The SIBPAIR method was found to have very high reliability with very small SEM values, and the SIBPAIR-based protocol also showed very high intra-rater, inter-rater, and inter-session reliability with small SEM. These results indicate that accurate and reliable measurements could be obtained by following the protocol regardless of the rater’s experience or time of measurement. This will be useful for foot assessment and subsequent applications, such as design and manufacture of customized orthoses or shoes. ? 2021 by the authors. Licensee MDPI, Basel, Switzerland. | - |
dc.relation.ispartof | Applied Sciences (Switzerland) | - |
dc.title | Test-retest reliability of sole morphology measurements using a novel single-image-based pin-array impression reconstruction method | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.3390/app11104447 | - |
dc.identifier.scopus | 2-s2.0-85106660082 | - |
dc.relation.journalvolume | 11 | - |
dc.relation.journalissue | 10 | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | journal article | - |
item.grantfulltext | none | - |
crisitem.author.dept | Biomedical Engineering | - |
crisitem.author.orcid | 0000-0003-3458-6049 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | College of Engineering | - |
顯示於: | 醫學工程學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。