標題: | Portable interactive pulse tactile recorder and player system | 作者: | Hsieh T.-C Wu C.-M Tsai C.-C Lo W.-C Wang Y.-M Smith S. SHANA SMITH |
關鍵字: | Artificial neural network;Empirical mode decomposition;Intrinsic mode functions;Pulse tactile player;Pulse tactile recorder;Cell proliferation;Diagnosis;Display devices;Functions;Mean square error;Neural networks;Display standards;Empirical Mode Decomposition;Intrinsic Mode functions;Pulse measurements;Root mean square errors;Tactile exploration;Tactile feedback;Vibration waveforms;Signal processing;heart rate;human;palpation;pressure;pulse rate;touch;Heart Rate;Humans;Neural Networks, Computer;Palpation;Pressure;Pulse;Touch | 公開日期: | 2021 | 卷: | 21 | 期: | 13 | 來源出版物: | Sensors | 摘要: | Pulse palpation is an effective method for diagnosing arterial diseases. However, most pulse measurement devices use preconfigured pressures to collect pulse signals, and most pulse tactile simulators can only display standard or predefined pulse waveforms. Here, a portable interactive human pulse measurement and reproduction system was developed that allows users to take arbitrary pulses and experience realistic simulated pulse tactile feedback in real time by using their natural pulse-taking behaviors. The system includes a pulse tactile recorder and a pulse tactile player. Pulse palpation forces and vibrations can be recorded and realistically replayed for later tactile exploration and examination. To retain subtle but vital pulse information, empirical mode decomposition was used to decompose pulse waveforms into several intrinsic mode functions. Artificial neural networks were then trained based on intrinsic mode functions to determine the relationship between the driving signals of the pulse tactile player and the resulting vibration waveforms. Experimental results indicate that the average normalized root mean square error and the average R-squared values between the reproduced and original pulses were 0.0654 and 0.958 respectively, which indicate that the system can reproduce high-fidelity pulse tactile vibrations. ? 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85108403047&doi=10.3390%2fs21134339&partnerID=40&md5=08200970df660a9fb2ce78fc7447bac5 https://scholars.lib.ntu.edu.tw/handle/123456789/598994 |
ISSN: | 14248220 | DOI: | 10.3390/s21134339 |
顯示於: | 機械工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。