https://scholars.lib.ntu.edu.tw/handle/123456789/620720
標題: | Single-wavelength reflected confocal and multiphoton microscopy for tissue imaging | 作者: | Chen W.-L. Chou C.-K. Lin M.-G. Chen Y.-F. Jee S.-H. Tan H.-Y. Tsai T.-H. Kim K.-H. Kim D. So P.T.C. SUNG-JAN LIN CHEN-YUAN DONG |
關鍵字: | Multiphoton fluorescence; Optical microscopy; Reflected confocal imaging; Second-harmonic generation | 公開日期: | 2009 | 卷: | 14 | 期: | 5 | 來源出版物: | Journal of Biomedical Optics | 摘要: | Both reflected confocal and multiphoton microscopy can have clinical diagnostic applications. The successful combination of both modalities in tissue imaging enables unique image contrast to be achieved, especially if a single laser excitation wavelength is used. We apply this approach for skin and corneal imaging using the 780-nm output of a femtosecond, titanium-sapphire laser. We find that the near-IR, reflected confocal (RC) signal is useful in characterizing refractive index varying boundaries in bovine cornea and porcine skin, while the multiphoton autofluorescence (MAF) and second-harmonic generation (SHG) intensities can be used to image cytoplasm and connective tissues (collagen), respectively. In addition, quantitative analysis shows that we are able to detect MAF from greater imaging depths than with the near-IR RC signal. Furthermore, by performing RC imaging at 488, 543, and 633 nm, we find that a longer wavelength leads to better image contrast for deeper imaging of the bovine cornea and porcine skin tissue. Finally, by varying power of the 780-nm source, we find that comparable RC image quality was achieved in the 2.7 to 10.7-mW range. © 2009 Society of Photo-Optical Instrumentation Engineers. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-74049128998&doi=10.1117%2f1.3247157&partnerID=40&md5=f5c5b053682b87ff89453a4cc9b560f8 https://scholars.lib.ntu.edu.tw/handle/123456789/620720 |
ISSN: | 10833668 | DOI: | 10.1117/1.3247157 | SDG/關鍵字: | Autofluorescence; Clinical diagnostics; Confocal imaging; Connective tissues; Femtoseconds; Image contrasts; Imaging depth; Multi-photon microscopy; Multiphoton fluorescence; Multiphotons; Near-IR; Porcine skin; Porcine skin tissues; Single wavelength; Tissue imaging; Titanium sapphire laser; Collagen; Cytology; Harmonic generation; Image quality; Laser excitation; Musculoskeletal system; Optical microscopy; Refractive index; Titanium; Tissue; Bovinae; Sus; article; computer aided design; confocal microscopy; equipment; equipment design; evaluation; image quality; image subtraction; instrumentation; multiphoton microscopy; reproducibility; sensitivity and specificity; Computer-Aided Design; Equipment Design; Equipment Failure Analysis; Microscopy, Confocal; Microscopy, Fluorescence, Multiphoton; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Subtraction Technique |
顯示於: | 醫學院附設醫院 (臺大醫院) |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。