標題: | Pressure-impedance analysis: Assist the diagnosis and classification of ineffective esophageal motility disorder | 作者: | JIA-FENG WU I-JUNG TSAI Tong, TW YI-CHENG LIN CHIA-HSIANG YANG PING-HUEI TSENG |
關鍵字: | bolus transit; distal contractile to impedance integral ratio; esophageal manometry; ineffective esophageal motility; MULTICHANNEL INTRALUMINAL IMPEDANCE; MANOMETRY ANALYSIS; PARAMETERS | 公開日期: | 1-八月-2020 | 出版社: | WILEY | 卷: | 35 | 期: | 8 | 起(迄)頁: | 1317 | 來源出版物: | JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY | 摘要: | Background and Aim: We elucidated the clinical significance of distal contractile integral-to-esophageal impedance integral (EII) ratio (DCIIR) in ineffective esophageal motility (IEM) adult patients. Methods: We recruited 101 patients with IEM (48.38 ± 1.58 years) and 42 matched healthy volunteers (44.28 ± 1.85 years) in this case–control study. All subjects underwent esophageal high-resolution impedance manometry from October 2014 to May 2018. The diagnosis of IEM was based on the Chicago Classification version 3.0. The EII, EII ratio, and DCIIR were analyzed by matlab software. Results: The EII, EII ratio, and DCIIR calculated at an impedance threshold of 1500 Ω (EII1500, EII ratio1500, and DCIIR1500, respectively) were significantly lower in the IEM group than in healthy controls (P < 0.0001, < 0.0001, and < 0.0001, respectively). Receiver operating characteristic analysis showed that DCIIR1500 < 0.008 mmHg/Ω, EII1500 > 71 000 Ω.s.cm, and EII ratio1500 > 0.43 were all predictive of IEM. Only DCIIR1500 < 0.008 mmHg/Ω remained significant in diagnosing IEM in the multivariate logistic regression analysis (odds ratio = 72.13, P < 0.001). The DCIIR1500 is negatively correlated with Eckardt score and the Reflux Disease Questionnaire (correlation coefficient = −0.2844 and −0.3136; P = 0.0006 and 0.0002, respectively). Receiver operating characteristic analysis further showed that a DCIIR1500 cut-off of 0.002 mmHg/Ω achieved the best differentiation between the IEM-alternans and IEM-persistens subtypes among IEM patients (P < 0.001). Conclusions: The novel pressure–impedance parameter of high-resolution impedance manometry, DCIIR1500, may assist in the diagnosis and classification of IEM and correlated with clinical symptoms. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/628663 | ISSN: | 0815-9319 | DOI: | 10.1111/jgh.14981 |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。