https://scholars.lib.ntu.edu.tw/handle/123456789/629725
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Rahman, Atiq Ur | en_US |
dc.contributor.author | Nemallapudi, Mythra Varun | en_US |
dc.contributor.author | CHENG-YING CHOU | en_US |
dc.contributor.author | Lin, Chih Hsun | en_US |
dc.contributor.author | Lee, Shih Chang | en_US |
dc.date.accessioned | 2023-03-25T09:25:29Z | - |
dc.date.available | 2023-03-25T09:25:29Z | - |
dc.date.issued | 2022-09-21 | - |
dc.identifier.issn | 00319155 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/629725 | - |
dc.description.abstract | Objective. Obtaining the intrinsic dose distributions in particle therapy is a challenging problem that needs to be addressed by imaging algorithms to take advantage of secondary particle detectors. In this work, we investigate the utility of deep learning methods for achieving direct mapping from detector data to the intrinsic dose distribution. Approach. We performed Monte Carlo simulations using GATE/Geant4 10.4 simulation toolkits to generate a dataset using human CT phantom irradiated with high-energy protons and imaged with compact in-beam PET for realistic beam delivery in a single-fraction (∼2 Gy). We developed a neural network model based on conditional generative adversarial networks to generate dose maps conditioned on coincidence distributions in the detector. The model performance is evaluated by the mean relative error, absolute dose fraction difference, and shift in Bragg peak position. Main results. The relative deviation in the dose and range of the distributions predicted by the model from the true values for mono-energetic irradiation between 50 and 122 MeV lie within 1% and 2%, respectively. This was achieved using 105 coincidences acquired five minutes after irradiation. The relative deviation in the dose and range for spread-out Bragg peak distributions were within 1% and 2.6% uncertainties, respectively. Significance. An important aspect of this study is the demonstration of a method for direct mapping from detector counts to dose domain using the low count data of compact detectors suited for practical implementation in particle therapy. Including additional prior information in the future can further expand the scope of our model and also extend its application to other areas of medical imaging. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IOP Publishing Ltd | en_US |
dc.relation.ispartof | Physics in Medicine and Biology | en_US |
dc.subject | EMISSION-TOMOGRAPHY; QUALITY-ASSURANCE; THERAPY; RANGE; RECONSTRUCTION; VERIFICATION; CT; UNCERTAINTIES; MODEL | en_US |
dc.title | Direct mapping from PET coincidence data to proton-dose and positron activity using a deep learning approach | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1088/1361-6560/ac8af5 | - |
dc.identifier.pmid | 35981556 | - |
dc.identifier.scopus | 2-s2.0-85139233736 | - |
dc.identifier.isi | WOS:000853993900001 | - |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/85139233736 | - |
dc.relation.journalvolume | 67 | en_US |
dc.relation.journalissue | 18 | en_US |
item.languageiso639-1 | en | - |
item.openairetype | journal article | - |
item.fulltext | no fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Biomechatronics Engineering | - |
crisitem.author.orcid | 0000-0002-5737-6960 | - |
crisitem.author.parentorg | College of Bioresources and Agriculture | - |
顯示於: | 生物機電工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。