Continuous monitoring of acid stratification during charge/discharge by holographic laser interferometry
Journal
Journal of Power Sources
Journal Volume
55
Journal Issue
2
Pages
243-246
Date Issued
1995
Author(s)
Abstract
The change in the acid concentration in the vertical direction in a lead/acid battery is monitored continuously during charge/discharge cycling by means of a holographic laser interferometry method. It is found that there is a difference in the acid distribution in the upper and lower parts of the electrolyte due to uneven reaction speeds and acid movement by natural convection. This causes an interesting re-emergence of an uneven distribution during the interval between charge and discharge. © 1995.