Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Science / 理學院
  3. Chemistry / 化學系
  4. The development of CE-MS and CEC-MS interfaces based on noncontinuous electrospray and chip-based microinjector
 
  • Details

The development of CE-MS and CEC-MS interfaces based on noncontinuous electrospray and chip-based microinjector

Date Issued
2007
Date
2007
Author(s)
Chen, Chao-Jung
DOI
en-US
URI
http://ntur.lib.ntu.edu.tw//handle/246246/51646
Abstract
Several approaches based on noncontinuous spray and chip-based microinjector have been developed to overcome the clogging problem in sheathless CE-MS, and to increase the throughput in CE and CEC-MS. To develop a more practical and sensitive CE-MS interface, a sheathless pulsed–ESI interface has been developed for coupling capillary electrophoresis (CE) with ion trap mass spectrometer (MS). In sheathless CE-MS, because the EOF in CE is about 50~250 nL/min, in order to meet the optimal flow rate of the sprayer, the orifice of the sprayer has to be tapered down to ~20 µm or less o.d. Nevertheless, the susceptibility of breaking or clogging of the tip during coating or sample analysis limits the application of the tapered tips having small orifices. The use of noncontinuous spray mode allows the use of a sprayer with a larger orifice thus alleviate the problem of column clogging during conductive coating and CE analysis. A pulsed ESI source operated at 20 Hz and 20% duty cycle was found to produce the optimal signals. For better signals, the maximum ion injection time in the ion-trap mass spectrometer has to be set to a value close to the actual spraying time (10 ms). Using a sprayer with 50 µm o.d., more stable and enhanced signals were obtained in comparison with continuous CE-ESI-MS under the same flow rate (150 nL/min). The utility of this design is demonstrated with the analysis of synthetic drugs by capillary electrophoresis-mass spectrometry (CE-MS). For increase the throughput in CE-MS, a multiplex electrophoresis–mass spectrometry using four low flow sheath liquid ESI sprayers has been developed. Because of low sample dilution and the producing of smaller droplets, low flow interface is known to outperform conventional sheath liquid interface in sensitivity and the tolerance of salts. In a low flow interface, the sprayer is very close to the MS entrance for better ion transmission and because of the limited space between the sprayer and the entrance aperture of the ESI source, multiplex can not be achieved with the conventional rotating plate approaches. Based on noncontinuous spray for each sprayer, the multiplex low flow system was achieved by applying ESI potential sequentially to the four low flow sprayers, resulting in only one sprayer being sprayed at any given time. The synchronization of the scan event and the voltage relays was accomplished by using the data acquisition signal from the ion trap mass spectrometer. By synchronization, the ESI voltage was provided to the sprayers sequentially according to the corresponding scan event. With this design, a four-fold increase in analytical throughput was achieved. To perform fast analysis in CEC-MS approach, an approach to perform chip-based packed CEC-MS was proposed. This fast CEC-MS approach was based on a chip-based microinjector and a short fritless CEC column. Unlike integrated CEC chip, a chip-based poly-(dimethylsiloxane) (PDMS) microinjector was incorporated with a short fritless packed CEC column. By taking the advantages of small sample plug produced in channel cross intersection, automation in sample injection and separation, and fast separation because of a short CEC column, the proposed approach not only preserved the merits of chip analysis (fast separation and automation) but avoid the difficulty in packing ODS particles inside a chip. For better ESI sensitivity, this device was coupled with MS using a low flow sheath liquid interface. The potential and limitation of this device were evaluated in the analysis of a peptide mixture. To develop a more reliable sample loading method and to increase the throughput in sampling, a flow injection sampling method has been implemented for fast CEC-MS analysis. Because of the high back pressure of the CEC column, sample from the syringe pump will flow only into the sampling and waste channel. Therefore, a sample plug was formed according to the length of the sampling channel. With the incorporation of a six-port valve and a syringe pump to the chip microinjector, sample was delivered to the sampling channel at a flow rate of 1.56 µL/min. This simple and semi-automation system allows rapid sampling and high sample throughput. The potential and limitations were demonstrated in the analysis of peptides and protein digestion.
Subjects
毛細管電泳-質譜
脈衝式電噴灑
無鞘流式電噴灑界面
序列式噴灑
低流速鞘流界面
多通道分析
毛细
管電層質譜
晶片式微注射器
Capillary electrophoresis-mass spectrometry
Pulsed electrospray
Sheathless electrospray
Sequential spray
Low flow sheath liquid interface
Multichannel analysis
High throughput
Capillary
electrochromatography-mass spectrometry
Chip microinjector
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-96-F91223017-1.pdf

Size

23.31 KB

Format

Adobe PDF

Checksum

(MD5):9aeefdd4c54ffa5fa5813c11018f7bd2

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science