An Implantable Electrical Stimulation Probe with Bendable Split Anchors via Residual Stress

Date Issued
2014
Date
2014
Author(s)
Chen, Yu-Yen
URI
http://ntur.lib.ntu.edu.tw//handle/246246/263174
Abstract
Literature statistics showed that the chance for a person to suffer from low back pain could be up to 54%~80%, and the annual cost on low back pain treatment has 7% annual growth since 1990. These statistics indicate that the needs for low back pain treatment have been increasing. Low back pain can be effectively relieved by pharmacological treatment. However, this type of treatment may cause lots of side effects. Thus, researchers have been seeking other ways for low back pain relief. Neural probes have been widely used for recording and stimulating the specific sites of brains through electrical signal. Studies showed that electrical stimulation on specific neural tissues can evoke different reactions. For clinical low back pain treatment, the target nerve is treated with one-time stimulation, whose therapeutic effect is not permanent. Patients will need the stimulation surgery every 3 to 6 months to suppress the pain. Thus, implantable stimulation systems have been developed for different long-term neural electrical stimulation treatments, such as for Parkinson’s disease and sciatica. However, since implanting surgeries are often invasive, many minimally invasive surgical procedures are conducted nowadays, in order to reduce the size of incisions. This paper presents a bipolar electrode probe used for implantable nerve stimulation treatments in minimally invasive surgeries. The probe is composed of a flexible printed circuit substrate and a fabricated SU-8 layer. This probe features a tweezer-like mechanism caused by residual stress in SU-8 film, which will fix the probe to the target nerve. There are stripes on the SU-8 film so that the residual stress nets in a single direction and forms a curve. In addition, a film of gelatin nanofibers, produced via electrospinning, covers the fixed ends of the probe anchors for cell growth to ensure long-term fixation in the body. In the experiment of the cell culture, the gelatin fibrous membrane is proven to have good biocompatibility and mechanical properties for cell culture. Adhesion and growth of 3T3 fibroblast cells on the membrane is effective. Thus, this cell scaffold attached on the probe should reach expected efficacy. A modified Stoney’s formula is established for estimating residual stress in the SU-8 film. The SU-8 thickness was measured with a scanning electron microscopy (SEM); the radius of curve was computed by trigonometry, and the Young’s moduli of SU-8 and flexible printed circuit (FPC) were determined by a nanoindenter. The thicknesses and radii are variable, while the Young’s moduli for FPC and SU-8 were mostly constant at 1.37 GPa and 4.7-5.2 GPa, respectively. With the revised Stoney’s formula, the residual stress could then be calculated. The results of experiment show that there are no obvious relationship between the thickness of the film and the radius of curvature. The residual stress of the SU-8 film is affected by the film thickness. Thus, the deformation of bendable split anchor in the probe cannot be controlled by SU-8 film thickness, but the residual of the SU-8 film increase with increasing film thickness. In the experiment of holding strength test, the breaking force is dominated by the deformation of the bendable split anchors in the probe. The deformation of the bendable split anchor has an optimum holding strength. The experiment results show that breaking forces of the curved probe are higher than plane probe. Breaking force of the plane probe is 0.299 N, and normalized breaking force is 0.198. The probes with the curvature heights of 10.29 mm and 14.24 mm have the breaking forces of 0.368 N and 0.398 N, respectively; the normalized breaking force is 0.24 and 0.26, which are 22.7% and 31.3% higher than that of the plane probe, respectively. The probes with curvature heights between 13 mm and 14 mm have maximum average breaking force about 0.258. In the implanting process, the impedance of the probe should be measured using low-frequency signal in order to determine whether the probe touches the target nerve.
Subjects
神經電刺激
植入式探針
靜電紡絲
生物相容性
明膠纖維薄膜
殘餘應力
SU-8膜
微創手術
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-103-R01522525-1.pdf

Size

23.54 KB

Format

Adobe PDF

Checksum

(MD5):c15d4bc32a5fe4d01c3aa77d1d187ec7

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science