  4. Novel Strategies to Improve HIFU Therapy Efficiency: Real-time HIFU Focus Localization, Protein Denature Monitoring, Minimizing Thermal Injuries of Superficial Structures, and Enlarging Ablation Lesions Using Ultrasound Contrast Agent
 
  • Details

Novel Strategies to Improve HIFU Therapy Efficiency: Real-time HIFU Focus Localization, Protein Denature Monitoring, Minimizing Thermal Injuries of Superficial Structures, and Enlarging Ablation Lesions Using Ultrasound Contrast Agent

Date Issued
2007
Date
2007
Author(s)
Wu, Chih-Ching
DOI
zh-TW
URI
http://ntur.lib.ntu.edu.tw//handle/246246/61468
Abstract
One of the main problems encountered when using conventional B-mode ultrasound (US) for targeting and monitoring purposes during ablation therapies employing high-intensity focused US (HIFU) is the appearance of strong interference in the obtained diagnostic US images. In this study, instead of avoiding the interference noise, we demonstrate how we used it to locate the focus of the HIFU transducer in both in-vitro tissue-mimicking phantoms and an ex-vivo tissue block. We found that when the B-mode image plane coincided with the HIFU focal plane, the interference noise was maximally converged and enhanced compared with the off-focus situations. Stronger interference noise was recorded when the angle between the US image plane and the HIFU axis was less than or equal to 90. By intentionally creating a target (group of bubbles) at the 3.5-MHz HIFU focus (7.1 mm in length and 0.7 mm in diameter), the position of the maximal noise convergence coincided well with the target. The differenced between the predicted focus and the actual one (bubbles) on x and z axes (axes perpendicular to the HIFU central axis, Fig. 1) were both about 0.9 mm. For y axis (HIFU central axis), the precision was within 1.0 mm. For tissue block ablation, the interference noise concentrated at the position of maximal heating of the HIFU-induced lesions. The proposed method can also be used to predict the position of the HIFU focus by using a low intensity output scheme before permanent changes in the target tissue were made. The utilization of magnetic resonance imaging (MRI) for HIFU not only real-time monitoring of HIFU ablation but also allows the evaluation of HIFU-induced lesions after treatment. Our study proposed an interleaved dual gradient-echo technique to simultaneously estimate temperature changes and magnetization transfer (MT) contrast, reflecting respectively heating conditions and degree of tissue damage during HIFU treatment. If the target hepatocellular carcinoma (HCC) is close to the surface of the liver, HIFU may overheat intervening tissue such as the diaphragm, abdominal wall, and skin. To avoid this complication, we propose inducing artificial ascites in the abdominal cavity so as to separate the liver from the peritoneum, and to serve as a heat sink to cool overlying structures and thereby avoid inducing permanent damage. Target tissue that was 10 mm below the liver surface was ablated in 12 New Zealand White rabbits: 6 in the experimental group and 6 in the control group. Artificial ascites was established in the experimental group by injecting normal saline into the abdominal cavity until the pressure reached 150 mmH2O. Artificial ascites not only reduced the probability and extent of thermal damage to intervening structures (P<0.05), but also had no adverse affect on the efficacy of HIFU ablation (P>0.05). One of the major disadvantages of HIFU ablation was the small lesion size and thus the long treatment duration. In this study, the effect of using ultrasound contrast agent (UCA) to enlarge the lesion size was studied both in vitro and in vivo. The mechanisms of lesion formation in the presence of UCA microbubbles were studied in vitro and in vivo.
Subjects
超音波顯影劑
磁造影引導
組織傷害
熱治療
ultrasound contrast agent
high-intensity focused ultrasound
MR guided
tissue damage
thermal therapy
interference
ablation
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-96-D92522001-1.pdf

Size

23.53 KB

Format

Adobe PDF

Checksum

(MD5):1dcf00551332661273b7fbbc0e5d5f90

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science