Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Chemical Engineering / 化學工程學系
  4. Integrating an enzyme-entrapped conducting polymer electrode and a prereactor in a microfluidic system for sensing glucose
 
  • Details

Integrating an enzyme-entrapped conducting polymer electrode and a prereactor in a microfluidic system for sensing glucose

Journal
Electroanalysis
Journal Volume
20
Journal Issue
6
Pages
635-642
Date Issued
2008
Author(s)
Nien P.-C.
Huang M.-C.
Chang F.-Y.
Ho K.-C.  
DOI
10.1002/elan.200704123
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/408656
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-54549124614&doi=10.1002%2felan.200704123&partnerID=40&md5=6491c29573f9b7f6bc31fab432072216
Abstract
In this study, the flow injection analysis was applied to the enzyme-entrapped electrode on a chip for sensing glucose. The on-chip microelectrode was fabricated by the standard photolithography in clean-room environment and the microfluidic channel height of 100 mm on the chip was formed by poly(dimethylsiloxane). The conducting polymer, poly(3,4- ethylenedioxythiophene), PEDOT, was electropolymerized to entrap the coexisting glucose oxidase (GOD) by cyclic voltammetry (CV). The amount of enzyme entrapped in the matrix measured spectroscopically was about 0.101 U/cm2. At a flow rate of 10 ml/hr, the working electrode (Pt/PEDOT/GOD, WE1) was set at 0.7 V (vs. Ag/AgCl) and sensing of H2O2 was carried out by injecting samples with various concentrations of glucose (Glu). A linear relationship between the sensing current and the glucose concentration, ranging from 1 to 20 mM, was obtained with a sensitivity of 8 nA mm-2 mM -1. The response time and the recovery time were about 30 and 230 s, respectively. For a single-potential test, the oxidation currents of 0.08 mM ascorbic acid (AA) and a blend of 0.08 mM AA and 10 mM Glu reached 31.3% and 145.5%, respectively, when compared with the oxidation current of 10 mM Glu alone. However, when a pre-reactor (WE2) was set at the same potential (0.7 V) before the main enzyme integrated electrode (WE1), the oxidation current for the above mixed solution reached 99.6% of the original one. ? 2008 Wiley-VCH Verlag GmbH & Co. KGaA.
Subjects
Activity measurement
Biosensor
Enzyme
Glucose
Interference
Microfluidic system
On-chip microelectrode
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science