Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Public Health / 公共衛生學院
  3. Environmental and Occupational Health Sciences / 環境與職業健康科學研究所
  4. Applying open-path FTIR with computed tomography to evaluate personal exposures. Part 1: Simulation studies
 
  • Details

Applying open-path FTIR with computed tomography to evaluate personal exposures. Part 1: Simulation studies

Journal
Annals of Occupational Hygiene
Journal Volume
49
Journal Issue
1
Pages
61-71
Date Issued
2005
Author(s)
CHANG-FU WU  
Yost M.G.
Hashmonay R.A.
Larson T.V.
Guffey S.E.
DOI
10.1093/annhyg/meh078
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-14944372783&doi=10.1093%2fannhyg%2fmeh078&partnerID=40&md5=b12847357cedaac01d6f4f6fcecf6538
https://scholars.lib.ntu.edu.tw/handle/123456789/602072
Abstract
This paper presents the theoretical background and the numerical evaluation results obtained using computed tomography coupled with open-path Fourier transform infrared (CT-FTIR) measurements to estimate personal exposures. In this simulation study, we first tested the one-dimensional scenario with a five-beam segment geometry. A series of Gaussian plumes and the corresponding path-integrated concentrations (PICs) were simulated. The personal exposures were estimated as the average of the point estimates calculated from the workers' locations and the concentration profiles reconstructed from the Smooth Basis Function Minimization algorithm. It was found that the running-average PIC updating strategy has similar performance as the spline PIC updating strategy. However, the latter strategy gives delayed estimates of the workers' exposures since it requires additional measurements before and after the time period of interest. In the two-dimensional scenario, we simulated a series of single-mode bivariate Gaussian plumes with a nine-beam radial geometry. The average of the estimated exposures from the CT-FTIR approach was close to the average of the true exposures. The concordance correlation factors between the true and estimated exposures were reasonably good (between 0.50 and 0.58). This study demonstrated that the CT-FTIR approach is feasible for industrial hygiene monitoring.
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science