Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Biomedical Engineering / 醫學工程學系
  4. Biomechanical Studies of Stability of Lumbar Spinal Dynamic Stabilizer
 
  • Details

Biomechanical Studies of Stability of Lumbar Spinal Dynamic Stabilizer

Date Issued
2011
Date
2011
Author(s)
Liu, Chun-Hsien
URI
http://ntur.lib.ntu.edu.tw//handle/246246/254865
Abstract
Summary of Background Data: Fusion surgery is often used to treat unstable spinal diseases. Fusion surgery usually decreases the motion of the implanted levels and induces compensation behaviors at the adjacent levels. It is wildly believed that the excess motions at the adjacent levels cause disc degeneration. Some dynamic devices, ex. Dynesys system, have been developed to solve the problems by preserving motion at the implanted levels. However, the flexibility of these products varies and their performances on reducing adjacent disc degeneration are still absurd. Objective: The purpose of this study is to find the proper flexibility of posterior lumbar dynamic stabilizers by evaluating the neutral zone, range of motion, intradiscal pressure and intervertebral foramen area of the implanted and adjacent motion segments. Materials and methods: Eight 4-level (L2-L5) lumbar spine were dissected from 6-month old pigs. All soft tissues except the surrounding ligaments and facet capsule were carefully removed. Specimens were wrapped in saline-soaked gauze and stored in the freezer until the experiment. The flexion / extension angular displacement of the specimen in the intact status were measured under 8 Nm of pure moment. Then the specimen was injured at L3-L4 level by damaging the facet joints and surrounding ligaments. The angular flexion/extension displacement obtained from the specimen in the intact status under 8 Nm of pure moment was applied to the specimens in the injured status and consecutively in 5 levels of constrained status which was controlled by a self-designed adjustable dynamic stabilizer implanted at L3-L4. The flexion / extension motion of L3-4 was constrained to be 0%, 20%, 40%, 60%, and 80 % of the flexion / extension motion of the injured status. The intersegmental neutral zone (NZ), range of motion (ROM), changes of intradiscal pressure (det IDP) and changes of intervertebral foramen area (det IFA) of the implanted and adjacent cranial/caudal motion segments were calculated. The IDP was measured by in-house 20 G needle pressure transducers inserted into the disc. The intervertebral foramen area was calculated based on lateral radiographys. The “det IDP” and “det IFA” was defined as the difference of IDP / IFA before and after the angular displacement loading. Results: (1) During flexion. The NZ, ROM and the det IDP of the implanted and the adjacent cranial / caudal motion segments decreased with the increase of motion at the implanted level. The ROMs of the implanted and adjacent cranial/caudal motion segments in the status of 60% constrained motion at the implanted level were the same as those in the intact status. The det IDPs of the implanted and adjacent cranial/caudal motion segments in the status of 40%, 60% and 80% constrained motions were less than those in the intact status. The det IFAs of all motion segments in the injured and 5 constrained status were similar to those in the intact status. (2) During extension. The NZ, ROM and det IFA of the adjacent cranial and caudal motion segments decreased with the increase of motion at the implanted segment. The ROMs of the implanted and adjacent cranial/caudal motion segments in the status of 40% constrained motion at the implanted segment were the same as those in the intact status. The det IFAs of the implanted and adjacent cranial/caudal motion segments in the status of 60% and 80% constrained motions of the implanted segments were less than those in the intact status. The det IDPs of all motion segments in the injured and 5 constrained status were similar to those in the intact status. Conclusions: It is found that 60% constrained flexion motion and 40% constrained extension motion at the implanted level induce least compensation ROM, IDP change or IFA change at the adjacent cranial and caudal levels without violating the stability at the implanted level. The result of this study is expected to be helpful for the development of new dynamic stabilization systems.
Subjects
Non-Fusion Surgery
Range of Motion
Intradiscal Pressure
Foramen Size
Neutral Zone
Biomechanics
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-100-R98548019-1.pdf

Size

23.54 KB

Format

Adobe PDF

Checksum

(MD5):c3556e520bf6bf46befea13d62a8bd03

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science