Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Environmental Engineering / 環境工程學研究所
  4. Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests
 
  • Details

Evaluation of ozone generation and indoor organic compounds removal by air cleaners based on chamber tests

Journal
Atmospheric Environment
Journal Volume
45
Journal Issue
1
Pages
35-42
Date Issued
2011
Author(s)
Yu, Kuo-Pin
Lee, Grace Whei-May
Hsieh, Ching-Pei
Lin, Chi-Chi
WHEI-MAY LEE  
DOI
10.1016/j.atmosenv.2010.09.051
URI
http://www.scopus.com/inward/record.url?eid=2-s2.0-78449263535&partnerID=MN8TOARS
http://scholars.lib.ntu.edu.tw/handle/123456789/363139
Abstract
Ozone can cause many health problems, including exacerbation of asthma, throat irritation, cough, chest ache, shortness of breath, and respiratory infections. Air cleaners are one of the sources of indoor ozone, and thus the evaluation of ozone generated by air cleaners is desired significant issue. Most evaluation methods proposed are based on chamber tests. However, the adsorption and desorption of ozone on the wall of test chamber and the deposition of ozone resulted from the surface reaction can influence the evaluation results. In this study, we developed a mass balance model that took the adsorption, desorption and deposition of ozone into consideration to evaluate the effective ozone emission rates of six selected air cleaners. The experiments were conducted in a stainless steel chamber with a volume of 11.3m3 at 25°C and 60% relative humidity. The adsorption, desorption and deposition rate constants of ozone obtained by fitting the model to the experimental data were ka=0.149±0.052mh-1, kd=0.013±0.007h-1, and kr=0.050±0.020h-1, respectively. The effective ozone emission rates of Air Cleaners No. 1, 2, and 3 ranged between 13,400-24,500μgh-1, 7190-10,400μgh-1, and 4880-6560 μgh-1, respectively, which were more stable than those of No.4, 5, and 6. The effective ozone emission rates of Air Cleaners No. 4, 5, and 6 increased with the time of operation which might be relevant to the decrease of ozone removal by the "aging" filter installed in these cleaners. The removal of toluene and formaldehyde by these six air cleaners were also evaluated and the clean air delivery rates (CADRs) of these two pollutants ranged from non-detectable to 0.42±0.08m3h-1, and from non-detectable to 0.75±0.07m3h-1, respectively. The CADRs showed an insignificant relationship with the effective ozone emission rates. Thus, the removal of toluene and formaldehyde might be resulted from the adsorption on the filters and the decomposition by the high-voltage electric discharge or the ionization that generated ozone. ? 2010 Elsevier Ltd.
Subjects
Air cleaner; Chamber test; Indoor, volatile organic compounds; Ozone
SDGs

[SDGs]SDG3

Other Subjects
Chamber test; Clean air; Evaluation Method; Evaluation results; Experimental data; High-voltage electric discharge; Mass balance model; Ozone emission; Ozone generation; Ozone removal; Relative humidities; Test chambers; Volatile organic; Adsorption; Atmospheric humidity; Desorption; Electric discharges; Formaldehyde; Indoor air pollution; Ozone; Rate constants; Stainless steel; Surface reactions; Testing; Toluene; Volatile organic compounds; Air cleaners; formaldehyde; organic compound; ozone; toluene; adsorption; atmospheric deposition; desorption; emission; experimental study; filter; formaldehyde; health risk; indoor air; infectious disease; ionization; numerical model; organic compound; ozone; pollutant removal; relative humidity; toluene; volume; air pollution; air pollution control; article; atmospheric deposition; decomposition; desorption; humidity; priority journal
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science