  4. Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound
 
  • Details

Breast Cancer Chemotherapy Response Evaluation Using 3-D Power Doppler Ultrasound

Date Issued
2008
Date
2008
Author(s)
Lei, Yung-Hsiang
URI
http://ntur.lib.ntu.edu.tw//handle/246246/183632
Abstract
Several imaging modalities such as mammography, ultrasound (US), and magnetic resonance imaging (MRI) have been applied to evaluating the therapeutic response of neoadjuvant therapy for breast cancer. In this paper, the three-dimensional (3-D) Doppler US is adopted for evaluating the vascularity. The conventional vascularity index (VI) method is usually used to evaluate the vascularity. From our experiments, this method could not have enough reproducibility for monitoring the chemotherapy response due to the artificial vessel noise by breath and heartbeat. Hence, a new vascularity evaluation method based on the vessel length is proposed to reduce the vessel noise in this paper. At first, the 3-D thinning algorithm for the vessel image is performed to extract the vessel skeleton and then the vessel lengths could be found from the skeleton as the vascularity. Nevertheless, this proposed vessel length information still does not have enough reproducibility due to the vessel noise. In order to improve the vessel reproducibility, a vessel noise reduction method is developed to analyze the vessel lengths. In the proposed noise reduction method, only the lengths of vessels larger than a threshold are counted. The threshold could be a fixed value or proportion to the maximum vessel radius. In the relative noise reduction method, the average reproducibilities of 20% and 10% reductions are 0.075 and 0.078 in our cases. The reproducibility of fixed threshold reduction by 5-pixel and 3-pixel are 0.119 and 0.097 respectively. The relative threshold reductions have better performance than the fixed threshold reductions. Furthermore, the response during the chemotherapy for a patient could also be evaluated by the changes of vessel lengths. The therapy evaluation result of 20% reduction is worse than that of 10% reduction. Therefore, we conclude that the 10% noise reduction method is a better evaluation method for the response of chemotherapy.
Subjects
noise reduction method
SDGs

[SDGs]SDG3

Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-97-R95922087-1.pdf

Size

23.32 KB

Format

Adobe PDF

Checksum

(MD5):6c0162ee1c11824a8dfb6848680698b7

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science