Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Environmental Engineering / 環境工程學研究所
  4. Evaluation of sono-electrocoagulation for the removal of Reactive Blue 19 passive film removed by ultrasound
 
  • Details

Evaluation of sono-electrocoagulation for the removal of Reactive Blue 19 passive film removed by ultrasound

Journal
Separation and Purification Technology
Journal Volume
165
Pages
107-113
Date Issued
2016
Author(s)
He, C.-C.
Hu, C.-Y.
Lo, S.-L.
SHANG-LIEN LO  
DOI
10.1016/j.seppur.2016.03.047
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/463293
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84962140625&doi=10.1016%2fj.seppur.2016.03.047&partnerID=40&md5=4c5e26c22c050289a26f7fa7d145e87b
Abstract
In this study, ultrasonic treatment was used to remove the passive film that formed on electrode surface during electrocoagulation (EC). The variation of electrode impendence was examined to evaluate the effect of passivation on EC and the ultrasound-electrocoagulation (sono-EC) process. The effects of operating parameters current density, pH and ultrasonic power on the removing efficiency in sono-EC were studied. A synthetic wastewater that contained Reactive Blue 19 dye was used in all experiments. The results demonstrated that the electrode impedance increased during the EC process but decreased during the sono-EC process, indicating that the passive film can be removed from the sacrificial electrode using ultrasound, causing the sacrificial electrode to generate more coagulant metal. Additionally, the ultrasound reduces the size of the metal hydroxide which in turn adsorb more contamination in synthetic wastewater. The SEM results show that ultrasound process could successfully remove the passive film on the plates. An intermittent ultrasonic process and double-type reactor were utilized to reduce the breaking of flocs in the system. A total of 97% of the RB19 was removed by intermittent sono-EC treatment at a current density of 18 mA/cm2, a pH of 5, an electrolysis time of 60 min and an ultrasound power of 150 W. Furthermore, the remove of the RB19 in the sono-EC process can be well expressed by a variable-order-kinetic model in the sono-EC system. In conclusion, ultrasonic equipment improves EC performance by removing the passive film.
SDGs

[SDGs]SDG6

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science