  4. Automated Full-field Breast Ultrasonography: The Past and The Present
 
  • Details

Automated Full-field Breast Ultrasonography: The Past and The Present

Journal
Journal of Medical Ultrasound
Journal Volume
15
Journal Issue
1
Pages
31--44
Date Issued
2007
Author(s)
Yi-Hong Chou
Chui-Mei Tiu
Jiayu Chen
RUEY-FENG CHANG  
DOI
10.1016/s0929-6441(08)60022-3
URI
http://scholars.lib.ntu.edu.tw/handle/123456789/331064
Abstract
Ultrasonography (US) has been used as an important adjunct to mammography (MG) for about 20 years, and during this period the diagnostic accuracy of US has increased remarkably. A conventional 2-dimensional MG only detects a summation of the X-ray opacity of the whole thickness of breast tissue over the entire breast, while US can separately detect the sonographic properties of the breast tissue in a fashion of contiguous slices. Automated full-field breast US (AFBUS) scanners were originally designed to effectively examine the breast in its entirety. Basically, AFBUS scanners are either prone or supine types. The old generation prone-type scanner consists of a large water-filled tank with the transducers mounted at the base. The patient is prone with the breast freely suspended in the warm water bath. The first prone-type AFBUS scanner (Octoson, 3 to 4.5 MHz; Ultrasound Institute, Sydney, Australia) was used from the late 1970s to late 1980s. It was a specially designed scanner comprising eight transducers immersed at the base of a large water tank. When used for breast scanning, a combination of three to four transducers was usually utilized to obtain an optimal compound image of the breast. The Labsonics scanner, a representative scanner of old-generation supine type, was a simple B-mode single-crystal high-resolution automated unit (7.5 MHz; Labsonics, Indianapolis, IN, USA) that was used from the mid-1980s to mid-1990s. The scanner provided multiple static images of the breast. The patient was supine and a water bag technique was used for sound wave transmission to the breast. With the rapid development of computer technologies, volumetric ultrasound can now be applied for the breasts. Volumetric ultrasound scanning of the breast has been proposed as a complimentary modality for breast cancer screening. There are two types: compression and suspension; the latter is not commercially available outside Japan (ASU-1004, Aloka, Japan). The compression type consists of two major designs: upright and supine types. In the upright-type compression method, the breast is placed and compressed between a film sheet and a compression plate. The new supine-type compression AFBUS scanning apparatus comprises a rigid and substantially stationary frame and a compressive membrane (a polyester film sheet). By manually pushing the frame to contact firmly with the relatively soft breast, the transducer can optimally scan the breast if a sufficient amount of gel is evenly applied on the breast surface, leaving minimal or no contact artifacts. It was originally hoped that AFBUS would rival MG as a screening procedure in asymptomatic women. However, the images obtained from the automated scanners of the old generation were of inferior quality to those generated by hand-held real-time scanners. Nevertheless, the current automated scanners equipped with high-frequency broadband transducers are still significantly competing with hand-held instruments. The current high-resolution AFBUS scanners can provide better demonstration of the breast anatomy and proper orientation and documentation of the lesions detected, and therefore better reproducibility and are good for follow-up studies. The volumetric data obtained can provide potential information for computer-aided detection and diagnosis of breast lesions. With current volumetric technologies, the AFBUS system can provide even higher detection rate of lesions including solid lesions and carcinomas. Interpretation of the imaging results from the volumetric AFBUS should be based on all the imaging data obtained. The current AFBUS scanners are easy to use and need only a short period of training, and the examination technique is especially suitable for technologists or sonographers to perform the whole scanning procedure. AFBUS may be used as an adjunct to MG or as baseline US examination of the breast and can play an important role in screening nonpalpable tumors in women with dense breasts. However, AFBUS in its current form cannot replace MG in detecting malignancy presenting as only microcalcifications.
SDGs

[SDGs]SDG6

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science