Abstract
In this dissertation, different chemical or biological molecules, including iodate, dopamine (DA), glycated hemoglobin (HbA1c), and nitrite were selected as the targets, and different materials were used to prepare the chemically modified electrodes (CMEs) for sensing them. Iodate is often added in table salts to prevent goiter. A composite film composed of the conducting polymer, poly(3,4-ethylenedioxythiophene) (PEDOT) and the mediator, flavin adenine dinucleotide (FAD), was prepared for the first time for modifying the glassy carbon electrode (GCE). This modified electrode was designated as GCE/PEDOT-FAD. Cyclic voltammetry (CV) and electrochemical quartz crystal microbalance (EQCM) analyses revealed that FAD was doped into the PEDOT film during the electrodepositon process. The optimal cycle number for preparing the modified electrode was determined to be 9. The amperometric detection of iodate was performed; the GCE/PEDOT-FAD showed a sensitivity of 0.78 μA μM-1 cm-2, a linear range of 4-140 μM, and a limit of detection (LOD) of 0.16 μM for iodate. Compared with the results in the literature obtained by using single FAD for sensing iodate, it can be said that the combination of PEDOT with FAD significantly improved the sensitivity and LOD. Eventually, the GCE/PEDOT-FAD was applied to detect iodate in a salt product. DA is a vital neurotransmitter; its abnormal transmission has been associated with several neurological disorders such as Parkinson’s disease and Huntington’s chorea. Boron doped carbon nanotubes (BCNTs) were utilized for modifying the screen printed carbon electrode (SPCE). The BCNTs were synthesized by an atmospheric carbothermal reaction, in which ammonia (in argon atmosphere) was used as the etching gas to create defects in the multi-walled carbon nanotubes (MWCNT), and boron trioxide was used as the boron source. Each CNT sample was dispersed in 0.5 wt.% Nafion® solution. The relationship between the boron doped amount and the electrocatalytic activity of the BCNT was explored for the first time; it was found that the oxidation peak current of DA is the highest on the BCNT (B 2.1 at.%) modified SPCE. Rotating disk electrode (RDE) analysis revealed that doping of 2.1 at.% boron into the MWCNT upgrades the electroactive surface area (Ae) and the standard rate constant (k0) by ca. 13%, respectively. DA sensing on the BCNT (B 2.1 at.%) modified SPCE was conducted; higher sensitivity (35.65 μA cm-2 μM-1) and lower LOD (0.017 μM) were obtained by using the differential pulse voltammetry (DPV), with respect to those obtained by using CV. The interfering effects of ascorbic acid and uric acid on DA sensing were also studied. HbA1c is an important index for assessing the long-term condition of diabetes monitoring. Screen printed gold electrode (SPGE) was chosen as the substrate, and Nafion® was dropped coated onto it as a selective material. Ferroceneboronic acid (FcBA) was utilized for recognizing HbA1c and providing the redox signal. Experimental results showed that the modification of Nafion® film effectively blocked the adsorption of hemoglobin (Hb) onto the SPGE; the main reason could be charge repulsion between Hb and Nafion®. The optimal layer of Nafion® film for modifying the SPGE was determined to be 3. Human whole blood was used for real sample test. The effect of HbA1c binding on the redox signal of FcBA was also investigated. It was verified that the binding with HbA1c is the main reason for causing the decrement of the redox signal. Furthermore, since the decrement of the reduction peak current is larger than that of the anodic peak current, it was deduced that HbA1c has stronger interaction with the oxidized FcBA (FcBA+). Nitrite is a significant index for assessing the urinary tract infection (UTI). For the convenience of clinical use, we tried to fabricate an electrochemical sensor to detect nitrite in the undiluted human urine samples. The conducting polymer, poly(3,4-(2’,2’-diethylpropylene)dioxythiophene) (PProDOT-Et2), was utilized to modify the SPGE to enhance its sensor performance. Since nitrite does not exist in the urine from healthy persons, nitrite was spiked into the urine samples for detection. It was found that the lowest concentration of nitrite that can be detect in the human urine by using the CV method is 250 μM, which is higher than the value can be achieved by the test paper coloring method, 20 μM. Different materials and different electrochemical sensing methods will be used to improve the sensor performance.
Subjects
碳材
化學修飾電極
導電高分子
摻雜
電化學式感測器
氧化還原媒子
SDGs

[SDGs]SDG3

Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-103-D98524002-1.pdf

Size

23.54 KB

Format

Adobe PDF

Checksum

(MD5):e6c732869d0f4f91e731fcfd4b35b731

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science