Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Electrical Engineering and Computer Science / 電機資訊學院
  3. Electronics Engineering / 電子工程學研究所
  4. Magnetic near-field probes with high-pass and notch filters for electric field suppression
 
  • Details

Magnetic near-field probes with high-pass and notch filters for electric field suppression

Journal
IEEE Transactions on Microwave Theory and Techniques
Journal Volume
61
Journal Issue
6
Pages
2460-2470
Date Issued
2013
Author(s)
Chou, Y.-T.
HSIN-CHIA LU  
DOI
10.1109/TMTT.2013.2258034
URI
http://www.scopus.com/inward/record.url?eid=2-s2.0-84878803670&partnerID=MN8TOARS
http://scholars.lib.ntu.edu.tw/handle/123456789/378008
Abstract
Several new types of low-cost and robust magnetic near-field probes manufactured in low-temperature co-fired ceramics (LTCC) are presented in this paper. Parallel C-shaped strips and their variations are inserted into the loop area in the front end of probes to achieve common-mode high-pass and notch filters for electric-field noise suppression. These probes with this kind of filter have excellent wideband electric field suppression. They are called high electric field suppression probes type A ~ D. The size of loop aperture in all probes is 100 μm long and 400 μm wide. The signal received from the loop is routed to a measurement apparatus through a semi-rigid coaxial cable with an outer diameter of 0.047 in. The flip-chip junction with low loss and good shielding is used between the probe head in LTCC and the semi-rigid coaxial cable. We take the probes over a 2000-μm-wide microstrip line as device-under-test to measure the probe characteristics. The isolation between electric and magnetic fields for a reference probe based on an old design using the same LTCC process is better than 30 dB from 0.05 to 12.65 GHz. The type A probe has two parallel C-shaped strips, it has better isolation of 35 dB from 0.1 to 11.05 GHz. Type C has one end of its strip shorted to ground, its 30-dB isolation frequency range can be extended to 0.05 ~ 17.8 GHz. With additional layout variation in type D, isolation can be improved to 40 dB up to 10.9 GHz. The spatial resolution for these probes is 140 μm when the distance between the metal surface of the microstrip line and the nearest edge of the loop is held at 120 μm. The calibration factors of the proposed probes are only slightly increased as compared with reference probe.
SDGs

[SDGs]SDG7

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science