Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. Oncology / 腫瘤醫學研究所
  4. Using Megavoltage Computed Tomography to Estimate Radiotherapy Dose for High-Density Metallic Implants
 
  • Details

Using Megavoltage Computed Tomography to Estimate Radiotherapy Dose for High-Density Metallic Implants

Journal
IEEE Transactions on Instrumentation and Measurement
Journal Volume
70
Date Issued
2021-01-11
Author(s)
Hsu, Yvonne Chiung Fang
Lee, Hsiao Ting
Wang, Yu Jen
Wang, Miao Ci
CHIAO-LING TSAI  
Wu, Jian Kuen
Huang, Tzu Jie
CHII-WANN LIN  
CHIA-HSIEN CHENG  
DOI
10.1109/TIM.2021.3061259
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/575456
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85101786785&doi=10.1109%2fTIM.2021.3061259&partnerID=40&md5=77ec4b0872a6e6f8aa4f84cfd886fd5b
URL
https://scholars.lib.ntu.edu.tw/handle/123456789/561587
Abstract
Streak artifacts in kilovoltage computed tomography (kVCT), originated from metallic implants, are reduced by megavoltage CT (MVCT). This study aimed to establish the image value-to-density table (IVDT) of MVCT and validate dose accuracy. The IVDT of MVCT was established with different physical densities (0.290-19.427 g/cm3) and compared with kVCT for doses. The Acuros external beam (AXB) algorithm was compared with the analytical anisotropic algorithm (AAA) for heterogeneity correction in MVCT. Based on the experimental results, the IVDT of MVCT showed good linearity. Dose overestimations for the metallic hip prosthesis in a water phantom were reduced from 2.6%/2.8% in kVCT_AAA, 1.8%/-0.7% in MVCT_AAA and to-0.7%/-0.3% in MVCT_AXB with 6-MV/10-MV photons, respectively. The predictive formulas were validated and highly correlated with the measured doses ($R^{2}= 0.9933$/0.9862 for 6-/10-MV photons, respectively). On average, the dose differences with a metallic eye shield on the Alderson radiation therapy phantom using 6-MV photon were reduced from 3.6% in kVCT_AAA to-1% in MVCT_AAA. In patient studies, the reductions of dose overestimations were from 28.6% and 7.4% to-3.9% with dental fillings, from 13.6% and-9% to-9.1% with the unilateral hip prosthesis, and from-25.3% and-5.9% to-4.3% with bilateral hip prostheses in kVCT_AAA, MVCT_AAA, and MVCT_AXB, respectively. In conclusion, MVCT with the AXB algorithm reduces metal artifacts on kVCT and plans accurate doses.
Subjects
Computed tomography | dose | kilovoltage | megavoltage | metallic implant
SDGs

[SDGs]SDG3

[SDGs]SDG6

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science