Abstract
An innovative cooling technology vibrating fans with a piezoelectric-magnetic source is investigated for the thermal management of electronics devices. The objective is to establish a cooling system that uses a piezoelectric-magnetic force as a vibrating source to drive multiple fans for cooling. The vibration driving force is generated by a piezoelectric material actuator coupled with multiple magnetic resonance forces. The cooling performance in terms of thermal resistance is evaluated and measured with different configurations, including the aspect ratio of the fan pitch (P/L) that ranges from 0.167 to 0.333 and the ratio of the gap between the fan tip and the heat sink (G/L) that ranges from 0.0167 to 0.0833 with different fan input powers ranging from 0.15W to 0.25W. The results indicate that multiple piezoelectric-magnetic fan (“MPMF”) system is efficient consuming low power with an improved thermal performance (76.7%) compared with natural convection. In addition, the optimum P/L can be found at 0.233 with different fan input powers. Furthermore, the optimum G/L is 0.05 whereas the optimum P/L is 0.233. The MPMF system can apparently decrease thermal resistance with the advantage of lower power consumption. The cooling performance and heat convection improvement for the MPMF system embedded in a heat sink are also evaluated at different fan tip locations. The results indicate that the fan tip location of the MPMF system at x/Sl =0.5 and y/Sh =0 is an optimum configuration, improving the thermal performance by 53.2% over natural convection condition for the fan input power of 0.1 W. The MPMF system breaks the thermal boundary layer and causes fluctuations inside the fins of the heat sink to enhance the average heat transfer coefficient. Moreover, the relationship between the convection improvement and the Reynolds number for the MPMF system has been investigated and transformed into a correlation line for nine different fan tip locations to provide a means of predicting the cooling performance for the MPMF system embedded in a heat sink.
Subjects
Resonance
The multiple piezoelectric–magnetic fan system
Cooling performance
Thermal resistance
Heat transfer coefficient
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-104-D96522031-1.pdf

Size

23.54 KB

Format

Adobe PDF

Checksum

(MD5):9bdb255d61c64d296c8ad684e212c5c2

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science