A Fast Frequency Measurement Circuit With Low Latency Developed Using FPGA
Journal
2025 Fourth International Symposium on Instrumentation, Control, Artificial Intelligence, and Robotics (ICA-SYMP)
Part Of
2025 Fourth International Symposium on Instrumentation, Control, Artificial Intelligence, and Robotics (ICA-SYMP)
Start Page
52
End Page
55
Date Issued
2025-01-15
Author(s)
Abstract
This paper presents the design and challenges of the statistical frequency measurement technique, which can be implemented using a field-programmable gate array (FPGA) board. The frequency measurement range is from 200 MHz to 715 MHz, with errors of less than 500 kHz. The latency of the first measurement result is only 360 ns, and consecutive measurement results of the same frequency signal can be obtained every 20 ns. Higher frequency accuracy can be effectuated by increasing the measurement latency.
Event(s)
4th International Symposium on Instrumentation, Control, Artificial Intelligence, and Robotics, ICA-SYMP 2025, Bangkok, 15 January 2025 through 17 January 2025. Code 206927
Subjects
field-programmable gate array (FPGA)
frequency measurement
reconfigurable
statistical method
Publisher
IEEE
Type