Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Biomedical Engineering / 醫學工程學系
  4. Biomechanical Study of Posterior Lumbar Interbody Fusion
 
  • Details

Biomechanical Study of Posterior Lumbar Interbody Fusion

Date Issued
2015
Date
2015
Author(s)
Chou, Wen-Kai
URI
http://ntur.lib.ntu.edu.tw//handle/246246/277544
Abstract
Posterior Lumbar Interbody Fusion (PLIF) is one of the most common surgical techniques employed to treat spinal deformity, degeneration and other instability related conditions. With the improved understanding of the spine biomechanics combined with the advancement of medical devices as well as the heightened expectations of the general public in pursuing better health and quality of life, the demand for PLIF is ever increasing in the modern society. Despite its well-published effectiveness in relieving clinical symptoms, the frequent development of secondary complications requiring revision surgery associated with PLIF inevitably reduces its clinical efficacy. It is therefore the primary aim of the current project to investigate the mechanisms underlying the development of secondary complications associated with PLIF through a series of in-vitro studies using both porcine and human cadaver specimens. The secondary aim of the project focused on the issues of implant failure and the development of adjacent segment disease after instrumentation and more importantly, discussed some plausible design modifications for future implant development. The first study of the project was an in-vitro cadaveric study designed to determine the exact role of the pedicular cortical bone composition and the screw-bone gap on the screw fixation failure. The results of the study identified a significant correlation between cortical bone area ratio and the screw pullout strength. Presented results also demonstrated that the fatigue loading induced screw-bone gap of 1 mm was sufficient to cause a significant decrease in the pullout strength. However, a cortical bone area ratio of 0.73 or higher in this group was able to preserve most of the screw-bone interfacial strength and subsequently may play an important role in preventing a complete implant failure in clinical practice. The second study in the series was an in-vitro fatigue-loading test utilizing porcine specimens to comparatively analyze the biomechanical performance of PEEK and Titanium rods construct subjected to a battery of fatigue loading testing. Based on the results, it was determined that the differences in biomechanical characteristics of PEEK and Titanium rods construct when subjected to fatigue loading. More specifically, the result is indicative of the potential benefits of the PEEK rods construct in reducing the risks of adjacent segment disease and implant failure rates. The final study in this series investigated the effect of altered mobility of the instrumented level and its consequential impact on the biomechanical characteristics of the adjacent segment levels. The outcome of the study demonstrated that the increasing range of motion at the instrumented level is associated with decreased compensatory motion and intra-discal pressure at the adjacent segments. It was also determined that a maximum of 4.04° into flexion and 2.41° into extension achieved maximum stability of the instrumented level coupled with minimal biomechanical compensatory at the adjacent levels. Such finding is of significant clinical value as it provides a guideline for the future design and development of more advanced spinal implants. Overall, the series of studies comprised in the current project investigated the possible mechanisms associated with the development of secondary complications post PLIF surgery and proposed plausible solutions to overcome each of the shortcomings by identifying more appropriate medical material or through modification of device design. The outcomes of the project provided valuable knowledge base and guidelines for clinicians performing PLIF and it is hoped that the presented information will ultimately assist in the reduction of secondary complications and revision surgery associated with PLIF and subsequently improve the long-term quality of life for the patients.
Subjects
Posterior lumbar interbody fusion
Biomechanics
Implant failure
Adjacent segment disease
SDGs

[SDGs]SDG3

Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-104-D97548007-1.pdf

Size

23.54 KB

Format

Adobe PDF

Checksum

(MD5):684a0bee5232c18e46c80715d3f50487

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science