  4. Effects of stent design on new clinical issue of longitudinal stent compression in interventional cardiology
 
  • Details

Effects of stent design on new clinical issue of longitudinal stent compression in interventional cardiology

Journal
Biomedical Microdevices
Journal Volume
16
Journal Issue
4
Pages
599-607
Date Issued
2014
Author(s)
Hsiao, H.-M.
Yeh, C.-T.
Wang, C.
Chao, L.-H.
DIAN-RU LI  
HAO-MING HSIAO  
DOI
10.1007/s10544-014-9862-4
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/447446
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84904122907&doi=10.1007%2fs10544-014-9862-4&partnerID=40&md5=9baac60f15d96dae5bb27ef39b09898f
Abstract
In recent years, interventional cardiologists have discussed over a new clinical issue called longitudinal stent compression (LSC), a failure mode not previously observed in coronary stents. This phenomenon occurs when the physician attempts to cross a deployed stent with a second device, causing the stent to dramatically shorten when two devices are accidentally entangled. While this phenomenon has been observed with a number of stent platforms, it seems more common with the Element stent. In this paper, a computational LSC model using finite element analysis was developed. A systematic investigation was conducted in attempts to quantify individual contribution of the stent design pattern, connector number, design parameter, and connector location on LSC. Computational simulations were performed on two representative coronary stents resembling Element and Endeavor for comparison. Simulation results show that the connector number plays the most significant role in LSC. The LSC could be easily tripled or quadrupled for the same stent design simply by increasing the connector number from two to three. The design pattern and design parameter play a secondary role in LSC, with the LSC improved by up to 30 and 65 %, respectively. It was also found that the LSC could be doubled for the Element stent simply by rearranging its connector location. This small design tweak could help improve the current Element LSC significantly, while still maintaining the majority of its excellent deliverability. These findings could provide great insights into this new clinical issue and help optimize future stent design to reduce the associated risk involved in LSC.
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science