Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Science / 理學院
  3. Physics / 物理學系
  4. Low-Frequency Noise Characterization of CoFeB/MgO/CoFeB MTJ-Based Perpendicular Field Sensor
 
  • Details

Low-Frequency Noise Characterization of CoFeB/MgO/CoFeB MTJ-Based Perpendicular Field Sensor

Journal
IEEE Transactions on Magnetics
Journal Volume
52
Journal Issue
7
Date Issued
2016
Author(s)
Das, B.
Lee, Y.C.
Li, L.C.
Yi-Shiou, L.
Suen, Y.W.
Horng, L.
Wu, T.-H.
CHING-RAY CHANG  
Wu, J.-C.
DOI
10.1109/TMAG.2016.2539422
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/436485
URL
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84977071118&doi=10.1109%2fTMAG.2016.2539422&partnerID=40&md5=4eac8a95935c67da16d7b1798e497dc5
Abstract
We report low-frequency electrical resistance noise of Co40Fe40B20/MgO/Co20Fe60B20-based magnetic tunnel junction field sensors with reference and sensing layer magnetization directions along the out-of-plane and in-plane directions, respectively. The devices are fabricated using the sputter deposition and conventional lithography techniques with a short axis of ∼ 6 μ m long and long axes of ∼ 6-12 μm long. Noise power spectra under different bias currents indicate increase in noise power with increasing bias current. A close 1/f dependence of the noise according to Hooge's relation, SV(f)= AV2/fα (A is Hooge's like constant) is observed with an average value of α = 1.03.0.08. In smaller devices, the magnetic field dependence of noise amplitude follows similar trend of magnetoresistance (MR) behavior without any distinct peak near antiparallel-parallel states transition of the devices, which is generally observed for magnetic defects-induced resistance fluctuation. The experimental observations infer the resistance noises in those devices that are related to the defects associated with the spin independent charge trapping at structural defects near or in the barrier layer. The device with the smallest lateral size exhibits the Lorentzian contribution, whereas the device with the largest size shows magnetic contribution in total noise. Numerically deduced magnetic fluctuations Δ Brms of all the devices shows an average magnetic fluctuation of ∼ 10 nT except for one device. The devices show the highest MR% of ∼ 27 % under perpendicular magnetic field with a dynamic range of ∼ 25 Oe and a sensitivity of ∼ 0.3%/Oe. The observed low-frequency noise levels are suitable for the perpendicular field detection application and can be reduced more by improving the crystallinity of the device films stacks and their interfaces.
SDGs

[SDGs]SDG7

Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science