Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. Physical Therapy / 物理治療學系所
  4. Fatigue Resistance Analysis of Tibial Baseplate in Total Knee Prosthesis - an in Vitro Biomechanical Study
 
  • Details

Fatigue Resistance Analysis of Tibial Baseplate in Total Knee Prosthesis - an in Vitro Biomechanical Study

Resource
CLINICAL BIOMECHANICS v.21 n.2 pp.147-151
Journal
CLINICAL BIOMECHANICS
Journal Volume
v.21
Journal Issue
n.2
Pages
147-151
Date Issued
2006
Date
2006
Author(s)
YU, TZAI-CHIU
HUANG, CHANG-HUNG
HSIEH, CHIA-HSUN
LIAU, JIANN-JONG
HUANG, CHUN-HSIUNG
CHENG, CHENG-KUNG
URI
http://ntur.lib.ntu.edu.tw//handle/246246/93749
Abstract
Background Tibial baseplates were occasionally reported with clinical fatigue failures. This study postulated that tibial baseplate of a specific mobile bearing design with a uniform thickness across the baseplate offers more fatigue resistance than the fixed-bearing design. Tibial baseplates of a fixed bearing and a mobile bearing design were fatigue- tested in vitro to study their fatigue resistance. Methods. Five samples of each design were tested under a sinusoidal loading between 90 N and 900 N at 30 Hz till failure or 10 million cycles. Experimental setup followed a standard published test method. Scanning electron microscope was used for inspecting the fracture surface of the failed baseplate . Findings. Two baseplates of fixed bearing design failed before 10 million cycles. Fatigue crack advancement marks were visible on the fractured surface of the failed samples. The fractured cross-section showed that the failure started near the end of the fin, it was likely due to the stress concentration as stress singularity existed at a point of sudden geometrical change. Five mobile bearing baseplates passed the test. Design of the tibial baseplate without fin structure and with a uniform thickness across the whole baseplate could help reducing the incidence of fatigue failure. Interpretation. The prosthesis survival rate was influenced by the long-term integrity of the metallic part of the prostheses such as the tibial baseplate. This study revealed that the tibial baseplate of a mobile bearing design with a uniform thickness provided better fatigue resistance than fixed bearing one. Standardized fatigue screening of the tibial baseplate was considered important in designing knee prostheses. (c) 2005 Elsevier Ltd. All rights reserved.
Subjects
tibial baseplate
knee prosthesis
mobile bearing
fixed bearing
fatigue

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science