Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Engineering / 工學院
  3. Biomedical Engineering / 醫學工程學系
  4. Development of SPR-based chip for Room-temperature Nitric Oxide Gas Sensing
 
  • Details

Development of SPR-based chip for Room-temperature Nitric Oxide Gas Sensing

Date Issued
2009
Date
2009
Author(s)
Wu, Tsing-Hua
URI
http://ntur.lib.ntu.edu.tw//handle/246246/183722
Abstract
A study was conducted to use the cyclic voltammery (CV) method to deposit polymer on the SPR chips at different potential range, scanning cycles, and scanning rates. We proposed to design SPR sensing chip combined with the Poly(3,4-ethylenedioxythiophene) (PEDOT) thin film as a novel optical SPR gas sensor. Depending on the optimal design of PEDOT sensing film, it provided better SPR curve and sensitivity and be able to apply to application of nitric oxide (NO) detector, which is a critical index in asthma diagnostic, and environmental toxic gas sensor in the future.n this study, we used the electrochemical system to prepare the PEDOT thin film. PEDOT as a sensing film which working at room temperature, as compared to the need to operate at a high temperature metal or metal compound semiconductor, and it have advantage of high conductivity, low-cost and easy to manufacture, etc... In the experiment the chip we use with sweeping voltage from 0v to 0.88v, scan rate 200mV/s for 30 cycles. At the degree of 43.2?, the reflectance intensity are 0.707, 0.407, and 0.232 at different concentration of 100, 50, 25ppm NO gas and 0.55, 0.32, and 0.17 for NO2 gas, the detecting limit of this thin-film sensing chip is about 8 ppm of NO gas at room temperature, correlation coefficient, R2, of NO gas concentration versus SPR angle shift is 0.96; the result shows the intensity for NO gas sensing is larger than NO2 gas and faster reaction time. In the experiments of this thesis, we have successfully combined the PEDOT thin film with the SPR sensor to serve as a nitric oxide gas detector, this novel type gas sensor provides several advantages such as fast, reversible, room temperature and high sensitivity and is able to serve as an optical surface plasmon resonance gas sensor.
Subjects
Gas sensor
Nitric oxide
Poly(3,4-ethylenedioxythiophene) (PEDOT)
Surface plasmon resonance
Type
thesis
File(s)
Loading...
Thumbnail Image
Name

ntu-98-R96548045-1.pdf

Size

23.53 KB

Format

Adobe PDF

Checksum

(MD5):98d0526ebb1f597491686e0ee156d454

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science