  4. An improved electrochemical biosensing device architecture with ultra-thin and surface-modified dielectric stacking structure
 
  • Details

An improved electrochemical biosensing device architecture with ultra-thin and surface-modified dielectric stacking structure

Journal
Sensors and Actuators B: Chemical
Journal Volume
441
Start Page
137993
ISSN
0925-4005
Date Issued
2025-10
Author(s)
Xie, Qiuzhe
Chen, Guan-Ying
Chu, Chia-Fen
CHIH-TING LIN  
DOI
10.1016/j.snb.2025.137993
URI
https://scholars.lib.ntu.edu.tw/handle/123456789/732736
Abstract
Electrochemical capacitive sensors typically employ a planar electrode (PE) design on a dielectric substrate to evaluate target-induced changes in electrical double-layer (EDL) capacitance. However, as functional substrate areas shrink down to the nanoscale, sensor performance becomes highly sensitive to subtle variations in electrode shape and spacing. These present significant challenges for mass production. To address these issues, we introduce microwell array (MWA) capacitive sensors, which replace the conventional planar layout with a vertically stacked electrode design. This architecture preserves the benefits of nanoscale PE sensors while shifting the fabrication complexity of the sensing area from nanolithography to a more scalable chemical vapor deposition (CVD) process. To evaluate the performance compared to conventional PE-based sensors, we demonstrate biosensing application with the proposed MWA capacitive sensors. In brief, we develop a fabrication process that achieves ultra-thin dielectric layers of 240 nm and 60 nm between MWA electrodes, with fabrication reliability rates of 89.29 % and 50.71 %, respectively. Moreover, simulations reveal that the asymmetric electrode geometry of MWA sensors enhances near-surface current compared to PE sensors. We experimentally show that this effect becomes more pronounced as the dielectric layer thickness decreases. Finally, we also demonstrate that the lateral substrate of MWA sensors supports stable functionalization with an AEAPTES-biotin layer, as confirmed by surface potential measurements. Leveraging these technical advancements, the MWA sensor achieves Avidin and Streptavidin detection limit as 120 fM and 1.76 pM, respectively. These results underscore the potential of the proposed MWA capacitive sensors, demonstrating their superiority over conventional PE sensors for advanced biosensing applications.
Electrochemical capacitive sensors typically employ a planar electrode (PE) design on a dielectric substrate to evaluate target-induced changes in electrical double-layer (EDL) capacitance. However, as functional substrate areas shrink down to the nanoscale, sensor performance becomes highly sensitive to subtle variations in electrode shape and spacing. These present significant challenges for mass production. To address these issues, we introduce microwell array (MWA) capacitive sensors, which replace the conventional planar layout with a vertically stacked electrode design. This architecture preserves the benefits of nanoscale PE sensors while shifting the fabrication complexity of the sensing area from nanolithography to a more scalable chemical vapor deposition (CVD) process. To evaluate the performance compared to conventional PE-based sensors, we demonstrate biosensing application with the proposed MWA capacitive sensors. In brief, we develop a fabrication process that achieves ultra-thin dielectric layers of 240 nm and 60 nm between MWA electrodes, with fabrication reliability rates of 89.29 % and 50.71 %, respectively. Moreover, simulations reveal that the asymmetric electrode geometry of MWA sensors enhances near-surface current compared to PE sensors. We experimentally show that this effect becomes more pronounced as the dielectric layer thickness decreases. Finally, we also demonstrate that the lateral substrate of MWA sensors supports stable functionalization with an AEAPTES-biotin layer, as confirmed by surface potential measurements. Leveraging these technical advancements, the MWA sensor achieves Avidin and Streptavidin detection limit as 120 fM and 1.76 pM, respectively. These results underscore the potential of the proposed MWA capacitive sensors, demonstrating their superiority over conventional PE sensors for advanced biosensing applications.
SDGs

[SDGs]SDG7

Publisher
Elsevier BV
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science