Repository logo
  • English
  • 中文
Log In
Have you forgotten your password?
  1. Home
  2. College of Medicine / 醫學院
  3. Physical Therapy / 物理治療學系所
  4. Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint
 
  • Details

Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint

Journal
Clinical Biomechanics
Journal Volume
17
Journal Issue
9-10
Pages
698-704
Date Issued
2002
Author(s)
JIANN-JONG LIAU  
Cheng C.-K.
Huang C.-H.
Lo W.-H.
DOI
10.1016/S0268-0033(02)00102-X
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-0036853009&doi=10.1016%2fS0268-0033%2802%2900102-X&partnerID=40&md5=925353084a9856c3c8d89b5e20d34ec1
https://scholars.lib.ntu.edu.tw/handle/123456789/505398
Abstract
To investigate the effect of inserting a Fuji pressure sensitive film into an artificial tibiofemoral joint on the actual contact mechanics. The experimental measurement and finite element analysis were used.Background. Although Fuji pressure sensitive film was widespread used for measuring the contact characteristics of artificial joint, how this measurement approaches actual contact characteristics has not yet been studied extensively. Two three-dimensional finite element models of an artificial tibiofemoral joint were constructed. The with-film-model was used to mimic the experimental setup and was verified by comparing the contact area and pressure on the simulated film calculated from finite element analysis to the measured one from the Fuji film (ultra-super low and medium grades) in the experimental test. Then the with-film-model was modified to the without-film-model in which the simulated film was removed. The contact characteristics on the film calculated from the with-film-model were represented to the measured one and the contact characteristics on the tibial component calculated from the without-film-model were represented to the actual one. The measured and actual contact characteristics were studied to investigate the effects of Fuji film on the actual contact characteristics in the tibiofemoral joint of knee prosthesis. The contact characteristics calculated from with-film-model was reasonable agreement with measured one by Fuji film in the experimental test. The maximum difference is 13% in maximum contact pressure under a load of 3000 N. The maximum difference of contact area and pressure between the model simulating actual contact circumstance and the model with inserting a Fuji film between contacting surface are 2.4% and 14% respectively. This study revealed that contact area and pressure of the tibiofemoral joint of knee prosthesis measured by Fuji pressure sensitive film could be simulated by finite element analysis. The measurement of contact area in the artificial joint by using ultra-super low grade Fuji film is overestimated its actual contact area by 1.2-2.4%, but the measurement of contact pressure by using medium grade Fuji film is underestimated its actual contact pressure by 8-14%. This study revealed that the ultra-super low grade Fuji film is a reliable sensor to measure the contact area and the medium grade film would underestimate its actual contact pressure in the artificial tibiofemoral joint. This finding can provide a better understanding of the reliability of Fuji film to measure the contact characteristics of artificial joint in the experimental test.
Type
journal article

臺大位居世界頂尖大學之列,為永久珍藏及向國際展現本校豐碩的研究成果及學術能量,圖書館整合機構典藏(NTUR)與學術庫(AH)不同功能平台,成為臺大學術典藏NTU scholars。期能整合研究能量、促進交流合作、保存學術產出、推廣研究成果。

To permanently archive and promote researcher profiles and scholarly works, Library integrates the services of “NTU Repository” with “Academic Hub” to form NTU Scholars.

總館學科館員 (Main Library)
醫學圖書館學科館員 (Medical Library)
社會科學院辜振甫紀念圖書館學科館員 (Social Sciences Library)

開放取用是從使用者角度提升資訊取用性的社會運動,應用在學術研究上是透過將研究著作公開供使用者自由取閱,以促進學術傳播及因應期刊訂購費用逐年攀升。同時可加速研究發展、提升研究影響力,NTU Scholars即為本校的開放取用典藏(OA Archive)平台。(點選深入了解OA)

  • 請確認所上傳的全文是原創的內容,若該文件包含部分內容的版權非匯入者所有,或由第三方贊助與合作完成,請確認該版權所有者及第三方同意提供此授權。
    Please represent that the submission is your original work, and that you have the right to grant the rights to upload.
  • 若欲上傳已出版的全文電子檔,可使用Open policy finder網站查詢,以確認出版單位之版權政策。
    Please use Open policy finder to find a summary of permissions that are normally given as part of each publisher's copyright transfer agreement.
  • 網站簡介 (Quickstart Guide)
  • 使用手冊 (Instruction Manual)
  • 線上預約服務 (Booking Service)
  • 方案一:臺灣大學計算機中心帳號登入
    (With C&INC Email Account)
  • 方案二:ORCID帳號登入 (With ORCID)
  • 方案一:定期更新ORCID者,以ID匯入 (Search for identifier (ORCID))
  • 方案二:自行建檔 (Default mode Submission)
  • 方案三:學科館員協助匯入 (Email worklist to subject librarians)

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science