The Application of Cyclone Structure with UVC Equipment on the Analysis of Indoor Air Quality
Journal
Proceedings - 2022 IEEE International Conference on Consumer Electronics - Taiwan, ICCE-Taiwan 2022
Part Of
Proceedings - 2022 IEEE International Conference on Consumer Electronics - Taiwan, ICCE-Taiwan 2022
Start Page
555
End Page
556
ISBN (of the container)
9781665470513
ISBN
9781665470506
Date Issued
2022-07-06
Author(s)
Lin-Hang Hsu
DOI
10.1109/ICCE-Taiwan55306.2022.9869001
Abstract
In this study, the bacteria is chosen and discussed. The experiment uses SolidWorks simulation to see the flow field, In this work, a UVC air cleaning device, consisting of a cyclone and a UV tube, was designed and the prototype was established. The device was tested experimentally. A single stage Anderson impactor was used to detect the concentration of airborne bacteria. According to the results from bacteria colony, after the incubation of 48 hours, the device was shown effective.
Event(s)
2022 IEEE International Conference on Consumer Electronics - Taiwan
Subjects
bacteria concentration
CFD
cyclone
SolidWorks flow simulation
UVC sterilization
Publisher
IEEE
Description
2022 IEEE International Conference on Consumer Electronics - Taiwan, ICCE-Taiwan 2022Taipei6 July 2022through 8 July 2022
Type