https://scholars.lib.ntu.edu.tw/handle/123456789/159677
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor | 職能治療學系 | en |
dc.contributor.author | HSIEH, CHING-JU | en |
dc.contributor.author | HO, EDDIE YI-TAU | en |
dc.contributor.author | LIN, KEH-CHUNG | en |
dc.contributor.author | YU, JY-HAW | en |
dc.contributor.author | 謝靜茹 | zh-tw |
dc.contributor.author | 何一滔 | zh-tw |
dc.contributor.author | 林克忠 | zh-tw |
dc.contributor.author | 尤之浩 | zh-tw |
dc.creator | 謝靜茹;何一滔;林克忠;尤之浩 | zh-tw |
dc.creator | HSIEH, CHING-JU;HO, EDDIE YI-TAU;LIN, KEH-CHUNG;YU, JY-HAW | en |
dc.date | 2010 | en |
dc.date.accessioned | 2012-07-13T02:14:50Z | - |
dc.date.accessioned | 2018-07-09T00:51:32Z | - |
dc.date.available | 2012-07-13T02:14:50Z | - |
dc.date.available | 2018-07-09T00:51:32Z | - |
dc.date.issued | 2010 | - |
dc.identifier.uri | http://ntur.lib.ntu.edu.tw//handle/246246/242060 | - |
dc.description.abstract | Purpose: To compare the visual functions and quality of life (QOL) in eyes with multifocal versus monofocal intraocular lens (IOL) implantation in Taiwan. Methods: A total of 61 patients with bilateral IOL implantation were divided into three groups as follows: ReSTOR (44 eyes), Tecnis ZM900 (36 eyes), SA60AT (42 eyes). All ophthalmic examinations were performed 3 months after IOL implantation. Visual functions included uncorrected and best corrected visual acuity (UVA/ BCVA) at 6 m, 70 cm and 33 cm, reports of spectacle independence, and contrast sensitivity (CS) with Rabin CS test. The Chinese version of the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) was measured. One-way ANOVA and Chi-square tests were used for data analysis. Results: The near UVA/BCVA of the multifocal groups were better than that of the monofocal group. Postoperative near spectacle independence of the multifocal groups (ReSTOR 90.9%; Tecnics ZM900 89.5%) was greater than that of the monofocal group (31.8%) (p<.05). The mean log CS value under glare conditions for the multifocal groups was worse than that of the monofocal group (ReSTOR 0.40 0.35; Tecnis ZM900 0.23 0.26; SA60AT 0.42 0.33, p<.05) Postoperative scores of NEI-VFQ-25 were high, but not significantly different between the 3 groups. Conclusions: The multifocal IOLs demonstrated excellent near vision with high spectacle independence. There was no compromised CS in dim and glare conditions and better vision -related QOL than monofocal IOLs. | en |
dc.language | zh-tw | en |
dc.language.iso | en_US | - |
dc.relation | 中華民國眼科醫學會雜誌 v.49 n.2 pp.183-191 | en |
dc.relation.ispartof | 中華民國眼科醫學會雜誌,v.49 | - |
dc.subject | multifocal intraocular lens | en |
dc.title | Quality-of-Life and Visual Function Assessment Following Cataract Extraction with Multifocal Versus Monofocal Intraocular Lens in Taiwan | en |
dc.title | 台灣研究植入多焦點人工水晶體在生活品質及視覺功能之成果 | zh-tw |
dc.relation.pages | 183-191 | - |
dc.relation.journalissue | n.2 | - |
item.languageiso639-1 | en_US | - |
item.grantfulltext | none | - |
item.fulltext | no fulltext | - |
顯示於: | 職能治療學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。