https://scholars.lib.ntu.edu.tw/handle/123456789/188284
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor | 內科 | en |
dc.contributor.author | Lo, Huey-Ming | en_US |
dc.contributor.author | JIUNN-LEE LIN | en_US |
dc.contributor.author | Lin, Fang-Yue | en_US |
dc.contributor.author | Tseng, Yung-Zu | en_US |
dc.creator | 林俊立;林芳郁;曾淵如 | zh-tw |
dc.creator | LIN, JIUNN-LEE;LIN, FANG-YUE;TSENG, YUNG-ZU | en |
dc.date | 2003 | en |
dc.date.accessioned | 2008-12-29T07:18:16Z | - |
dc.date.accessioned | 2018-07-11T05:28:37Z | - |
dc.date.available | 2008-12-29T07:18:16Z | - |
dc.date.available | 2018-07-11T05:28:37Z | - |
dc.date.issued | 2003-09-01 | - |
dc.identifier.uri | http://ntur.lib.ntu.edu.tw//handle/246246/95232 | - |
dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-0141742169&doi=10.1046%2fj.1460-9592.2003.t01-1-00282.x&origin=inward&txGid=ac2b3ee5a529c20e7697347dc6772169 | - |
dc.description.abstract | The P wave in the surface ECG represents atrial electrical activation and may be altered in certain pathological conditions. Atrial compartment operation has been used to convert chronic AF to sinus rhythm. However, this procedure may result in changes of impulse conduction in various atrial compartments and alters the P wave morphology. This study sought to elucidate the P wave changes after the atrial compartment operation for AF. Fifteen patients undergoing the atrial compartment operation for chronic AF were studied. In the operation, the atrium was divided into three compartments, namely the left atrium, the atrial septum including sinus and AV nodes, and the right atrial compartment. The anatomic connection between adjacent compartments were preserved at the posterior lower margin of incisions. The surface lead P waves were correlated with intracardiac recording and stimulation in various atrial compartments. Fifteen age- and sex-matched control patients without structural heart diseases were compared. The results showed that patients undergoing the atrial compartment operation had a prolonged P wave duration (190 +/- 27 vs 95+ /- 14 ms, P < 0.001), a prolonged PR interval (207 +/- 23 vs 155 +/ - 20ms, P < 0.001), and a shortened PR segment (17 19 vs 60 +/- 17ms, P < 0.001). The increase in P wave duration was primarily due to a conduction delay from the sinus node to the other atrial compartments as the conduction time from the high right atrium to the right atrial appendage was 132 +/- 57ms (vs 21 +/- 6ms for control, P < 0.001), and the conduction time from the high right atrium to the distal coronary sinus was 140 +/- 55ms (vs 70+/- 15ms, P < 0.001). However, the conduction from the high right atrium to the low septal right atrium, which were located in the same compartment, was not impaired. Also, the conduction in the AV node and His-Purkinje system were not impaired. The mean axis of P waves varied greatly, but was not statistically different from that of the control group ( 60 +/- 48degrees vs 52 +/- 18degrees, P > 0.05). Although the patients undergoing atrial compartment operation had a larger left atrial size, their P wave amplitude was smaller(1.0 +/- 0.3 vs 1.3 +/- 0.3 mm, P < 0.01), and an increased negative terminal force in V, was not seen (0.02 +/- 0.02 vs 0.02 +/- 0.01mm/s, P > 0.05). Alteration in P wave morphology was seen in 14 patients. All the P waves showed a biphasic configuration with an initial positive and a terminal slurred negative deflection in leads II, III, and aVF The terminal components represented the activation of right atrial appendage in 5 patients, the left atrium in 1, and the combined activation of right atrial appendage and the left atrium in 8 patients. The P wave morphology suggested that activation of both the right atrial appendage and the left atrial compartments proceeded in a caudocranial direction as a result of the atrial incisions. In conclusion , atrial compartment operation altered the conduction time and direction in the atria and resulted in characteristic P wave changes. | en_US |
dc.language | en-us | en |
dc.language.iso | en_US | en_US |
dc.relation | PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY v.26 n.9 pp.1864-1872 | en |
dc.relation.ispartof | PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | en_US |
dc.subject | ACTIVATION | en_US |
dc.title | Characteristic P Wave Morphology in Patients Undergoing the Atrial Compartment Operation for Chronic Atrial Fibrillation with Mitral Valve Disease | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1046/j.1460-9592.2003.t01-1-00282.x | - |
dc.identifier.pmid | 10.1046/j.1460-9592.2003.t01-1-00282.x | - |
dc.relation.pages | 1864 | en_US |
dc.relation.journalvolume | 26 | en_US |
dc.relation.journalissue | 9 | en_US |
dc.relation.pageend | 1872 | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairetype | journal article | - |
item.languageiso639-1 | en_US | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
crisitem.author.dept | Internal Medicine | - |
crisitem.author.dept | Internal Medicine-NTUH | - |
crisitem.author.orcid | 0000-0003-2148-3956 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。