https://scholars.lib.ntu.edu.tw/handle/123456789/201452
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor | 放射線科 | en |
dc.contributor.author | CHANG, YEUN-CHUNG | en |
dc.contributor.author | WANG, HAO-CHIEN | en |
dc.contributor.author | YANG, PAN-CHYR | en |
dc.creator | 張允中;王鶴健;楊泮池 | zh-tw |
dc.creator | CHANG, YEUN-CHUNG;WANG, HAO-CHIEN;YANG, PAN-CHYR | en |
dc.date | 2003 | en |
dc.date.accessioned | 2009-01-16T02:49:55Z | - |
dc.date.accessioned | 2018-07-12T05:35:01Z | - |
dc.date.available | 2009-01-16T02:49:55Z | - |
dc.date.available | 2018-07-12T05:35:01Z | - |
dc.date.issued | 2003 | - |
dc.identifier.uri | http://ntur.lib.ntu.edu.tw//handle/246246/96963 | - |
dc.description.abstract | Transthoracic needle biopsy (TNB) is usually avoided in the presence of pneumothorax. The authors performed computed tomography (CT)-guided transthoracic core biopsy in the presence of pneumothorax in 13 patients ( 4.9%) selected from 265 patients who received CT-guided TNB over 4 years. These iatrogenic pneumothoraces were induced by previous ultrasound (US)- guided TNB (n = 5), transbronchial lung biopsy (n = 4), and CT-guided biopsy (n = 4). The time interval between previous thoracic intervention and CT- guided TNB ranged from 0 hours to 9 days after transbronchial lung biopsy (average, 4 days). A diagnostic core biopsy was performed in 12 of the 13 patients. Seven lesions proved to be malignant and five were benign. Failure of CT-guided transthoracic core biopsy occurred in a single patient with a previous US-guided biopsy within 24 hours. This patients demonstrated a progressively enlarging pneumothorax and was treated with air aspiration with CT guidance. A successful second biopsy was performed 7 days later after full expansion of the lung. There were no complications related to the procedures. The authors' experience suggests that CT-guided transthoracic core biopsy using small-bore coaxial technique can be safely performed with high-diagnostic yield in patients with stable iatrogenic pneumothorax. | en |
dc.language | en-us | en |
dc.language.iso | en_US | - |
dc.relation | JOURNAL OF THORACIC IMAGING v.18 n.1 pp.21-26 | en |
dc.relation.ispartof | JOURNAL OF THORACIC IMAGING | - |
dc.subject | COMPUTED TOMOGRAPHY | en |
dc.subject | LUNG BIOPSY | en |
dc.subject | LUNG PNEUMOTHORAX | en |
dc.title | Usefulness of Computed Tomography-Guided Transthoracic Small-Bore Coaxial Core Biopsy in the Presence O Fa Pneumothorax | en |
dc.relation.pages | 21-26 | - |
dc.relation.journalvolume | v.18 | - |
dc.relation.journalissue | n.1 | - |
item.languageiso639-1 | en_US | - |
item.grantfulltext | none | - |
item.fulltext | no fulltext | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。