標題: | Automated Conformal Ultrasound Scanning for Breast Screening | 作者: | Ching-Yen Lee Tan-Loc Truong PAI-CHI LI |
關鍵字: | Conformal scanning; 3D camera; Robot arm; Pressure sensing | 公開日期: | 2018 | 出版社: | Springer Nature | 來源出版物: | Journal of Medical and Biological Engineering | 摘要: | © 2017, Taiwanese Society of Biomedical Engineering. Automatic ultrasound breast screening methods are now in use, but not all the existing systems can provide a complete breast scan including axillary lymph nodes. Moreover, the existing systems perform scanning with a fixed scanning path and manual transducer adjustment is often required. It is therefore important to develop a scan system adapted to the body shape automatically. The proposed system consists of a three dimension (3D) camera, a robot arm, a computer, and a clinical ultrasonic scanner. A proper scan area can be determined by manual selection or algorithm automatically. An adaptive scan path covering the selected scan area is generated based on body shape, and the ultrasound images were acquired at each imaging position. In addition, a pressure sensor is used to maintain the contact to ensure the examinee’s comfort during scanning. The proposed system is able to perform automatic scanning and adapt to front and side areas of the breast as well as the axillary area. By examining a breast phantom, approximately 75 s scan time was required for a scan area of 100 mm × 50 mm with scan speed of 5 mm/s. The proposed system could provide personalized ultrasound scanning and extend the scan area to include the axillary lymph nodes, which has not been achieved by existing automatic ultrasound scanning systems. The probe positions and orientations allows 3D volume-data reconstruction. In the future, computer aided detection software can be integrated with the proposed system for fully automated ultrasound breast screening. |
URI: | https://scholars.lib.ntu.edu.tw/handle/123456789/403583 | ISSN: | 16090985 | DOI: | 10.1007/s40846-017-0292-7 https://doi.org/10.1007/s40846-017-0292-7 |
SDG/關鍵字: | Body fluids; Cameras; Robotic arms; Scanning; 3-D cameras; Automatic scanning; Axillary lymph nodes; Computer aided detection; Pressure sensing; Robot arms; Ultrasonic scanners; Ultrasound scanning; Ultrasonic applications; algorithm; Article; automated conformal ultrasonography; automation; breast cancer; calibration; cancer screening; contact angle; echomammography; robotics; three dimensional imaging |
顯示於: | 生醫電子與資訊學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。