https://scholars.lib.ntu.edu.tw/handle/123456789/483818
標題: | Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke | 作者: | YI-MIAU CHEN YI-JING HUANG CHIEN-YU HUANG Lin G.-H. Liaw L.-J. SHIH-CHIEH LEE CHING-LIN HSIEH |
公開日期: | 2017 | 卷: | 53 | 期: | 5 | 起(迄)頁: | 719-724 | 來源出版物: | European journal of physical and rehabilitation medicine | 摘要: | AIM: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke.BACKGROUND: The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores.DESIGN: Cross-sectional study.SETTING: The rehabilitation departments of a medical center and a community hospital.POPULATION: A total of 51 chronic stroke patients (64.7% male).CLINICAL REHABILITATION IMPACT: Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.RESULTS: The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors.METHODS: Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors.CONCLUSIONS: Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85032718653&doi=10.23736%2fS1973-9087.17.04463-X&partnerID=40&md5=27fd6ce6a6359935d82fc031cd407143 https://scholars.lib.ntu.edu.tw/handle/123456789/483818 |
ISSN: | 1973-9095 | DOI: | 10.23736/S1973-9087.17.04463-X | SDG/關鍵字: | age; aged; body equilibrium; cerebrovascular accident; community hospital; comparative study; cross-sectional study; daily life activity; disability; falling; female; human; male; middle aged; physiology; prevention and control; procedures; prognosis; psychology; psychometry; reproducibility; risk assessment; severity of illness index; sex factor; stroke rehabilitation; treatment outcome; university hospital; Academic Medical Centers; Accidental Falls; Activities of Daily Living; Age Factors; Aged; Cross-Sectional Studies; Disability Evaluation; Female; Hospitals, Community; Humans; Male; Middle Aged; Postural Balance; Prognosis; Psychometrics; Reproducibility of Results; Risk Assessment; Severity of Illness Index; Sex Factors; Stroke; Stroke Rehabilitation; Treatment Outcome |
顯示於: | 職能治療學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。