https://scholars.lib.ntu.edu.tw/handle/123456789/523155
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Chan C.-C. | en_US |
dc.contributor.author | Chou W.-C. | en_US |
dc.contributor.author | Chen C.-W. | en_US |
dc.contributor.author | YI-LWUN HO | en_US |
dc.contributor.author | YEN-HUNG LIN | en_US |
dc.contributor.author | Ma H.-P. | en_US |
dc.creator | Chan C.-C.;Chou W.-C.;Chen C.-W.;Yi-Lwun Ho;Lin Y.-H.;Ma H.-P. | - |
dc.date.accessioned | 2020-12-01T07:10:14Z | - |
dc.date.available | 2020-12-01T07:10:14Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | #VALUE! | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84868267285&doi=10.1109%2fNEWCAS.2012.6328979&partnerID=40&md5=020ed7b58868d83a776b3eea2fc1af21 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/523155 | - |
dc.description.abstract | An energy efficient prototype for diagnostic grade mobile ECG monitoring is developed. The prototype is developed with commercial discrete components to demo a patient centric medical environment. The prototype uses a mobile phone as a gateway to transmit the measured ECG data back to the medical cloud: Bluetooth for ECG sensor to the mobile phone, while 3G/WiFi for the mobile phone to the medical cloud. Therefore, the patients are not tied to the hospital or home, and can go outside for common life. The prototype can calculate on the mobile phone the RR intervals. More accurate RR, QRS interval can be obtained from server. The platform can also analyze the non-linear analysis of heart rate variability in patients with congestive heart failure based on multi-scale entropy. The size of the developed ECG sensor node is 75mm × 35mm × 20mm which is smaller than a credit card in area. The noise density of the amplifier is 22nV/Hz, and the total power of the sensor frontend is below 100uA. For wireless transmission, the Bluetooth module with a micro controller consumes current less than 110mA. The prototype can monitor ECG continuously for over 24 hours or with 3 weeks standby time. © 2012 IEEE. | - |
dc.relation.ispartof | 2012 IEEE 10th International New Circuits and Systems Conference, NEWCAS 2012 | - |
dc.subject.classification | [SDGs]SDG7 | - |
dc.subject.other | Blue-tooth module; Congestive heart failures; Credit cards; Discrete components; ECG data; ECG sensors; Energy efficient; Heart rate variability; Multiscales; Noise density; RR intervals; Standby time; Total power; Wireless transmissions; Bluetooth; Body sensor networks; Cellular telephones; Energy efficiency; Mobile phones; Sensor nodes; Electrocardiography | - |
dc.title | Energy efficient diagnostic grade mobile ECG monitoring | en_US |
dc.type | conference paper | en |
dc.identifier.doi | 10.1109/NEWCAS.2012.6328979 | - |
dc.identifier.scopus | 2-s2.0-84868267285 | - |
dc.relation.pages | 153-156 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_5794 | - |
item.openairetype | conference paper | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.fulltext | no fulltext | - |
crisitem.author.dept | Internal Medicine | - |
crisitem.author.dept | Internal Medicine-NTUH | - |
crisitem.author.dept | Internal Medicine | - |
crisitem.author.dept | Internal Medicine-NTUH | - |
crisitem.author.orcid | 0000-0002-8936-9570 | - |
crisitem.author.orcid | 0000-0001-8153-1441 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。