https://scholars.lib.ntu.edu.tw/handle/123456789/546853
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Lin, J.-H. | en_US |
dc.contributor.author | Tsai, T.-T. | en_US |
dc.contributor.author | Zeng, Q. | en_US |
dc.contributor.author | Chang, C.-Y. | en_US |
dc.contributor.author | Guo, J.-Y. | en_US |
dc.contributor.author | Lin, C.-J. | en_US |
dc.contributor.author | CHIEN-FU CHEN | en_US |
dc.creator | Lin, J.-H.;Tsai, T.-T.;Zeng, Q.;Chang, C.-Y.;Guo, J.-Y.;Lin, C.-J.;Chen, C.-F. | - |
dc.date.accessioned | 2021-02-04T02:29:56Z | - |
dc.date.available | 2021-02-04T02:29:56Z | - |
dc.date.issued | 2020 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.url?eid=2-s2.0-85094219906&partnerID=40&md5=da73e4fdb66caf018967314af257bb74 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/546853 | - |
dc.description.abstract | In this work, we demonstrate a multifunctional, portable, and disposable microfluidic device for blood typing and primary screening of blood diseases. Preloaded antibodies (anti-A, anti-B, and anti-D) interact with injected whole blood cells to cause an agglutination reaction that blocks a microslit in the microfluidic channel to accumulate red blood cells and form a visible red line that can be easily read to determine the blood type. Moreover, the different blood density and agglutination properties of normal and subtype blood groups, as well as different blood diseases, including anemia and polycythemia vera, generate different lengths of blood agglutination within the channels, which allows us to successfully screen these various conditions in as little as 2 min. The required blood volume for each test is just 1 μL, which can be obtained by minimally invasive finger pricking. This novel method of observing agglutinated red blood cells to distinguish blood types and diseases is both feasible and affordable, suggesting its promise for use in areas with limited resources. ? | - |
dc.relation.ispartof | ACS Sensors | - |
dc.subject | anemia; blood agglutination test; blood typing; point-of-care diagnosis; polycythemia | - |
dc.subject.classification | [SDGs]SDG3 | - |
dc.subject.other | Antigen-antibody reactions; Bacteria; Cells; Diagnosis; Fluidic devices; Microfluidics; Blood typing; Blood volumes; Micro-fluidic devices; Microfluidic channel; Minimally invasive; Polycythemia vera; Primary screening; Red blood cell; Blood; antigen antibody reaction; blood group typing; hematologic disease; human; lab on a chip; microfluidics; Agglutination; Blood Grouping and Crossmatching; Hematologic Diseases; Humans; Lab-On-A-Chip Devices; Microfluidics | - |
dc.title | A Multifunctional Microfluidic Device for Blood Typing and Primary Screening of Blood Diseases | en_US |
dc.type | journal article | en |
dc.identifier.doi | 10.1021/acssensors.0c00969 | - |
dc.identifier.pmid | 32786388 | - |
dc.identifier.scopus | 2-s2.0-85094219906 | - |
dc.relation.pages | 3082-3090 | - |
dc.relation.journalvolume | 5 | - |
dc.relation.journalissue | 10 | - |
item.openairetype | journal article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.fulltext | no fulltext | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Applied Mechanics | - |
crisitem.author.orcid | 0000-0001-7459-1649 | - |
crisitem.author.parentorg | College of Engineering | - |
顯示於: | 應用力學研究所 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。