Title: | Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars | Authors: | Chang H.-H. Lee M.-S. Hsu Y.-C. Tsai S.-J. CHUN-PIN LIN |
Keywords: | High-speed drilling device; Impacted third molar; Noise; Patient comfort; Piezosurgery device | Issue Date: | 2015 | Publisher: | Elsevier | Journal Volume: | 114 | Journal Issue: | 10 | Start page/Pages: | 929-935 | Source: | Journal of the Formosan Medical Association | Abstract: | Background/Purpose: Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Methods: Twenty patients (18 women and 2 men, 17-29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molars were divided into a control group (n = 20), in which the third molar was extracted by regular surgery using a high-speed handpiece and an elevator, and an experimental group (n = 20), in which the third molar was extracted by piezosurgery using a high-speed handpiece and a piezotome. The clinical parameters were evaluated by a self-reported questionnaire. The noise levels produced by the high-speed handpiece and piezotome were measured and compared between the experimental and control groups. Results: Patients in the experimental group had a better feeling about tooth extraction and force delivery during extraction and less facial swelling than patients in the control group. However, there were no significant differences in noise-related disturbance, extraction period, degree of facial swelling, pain score, pain duration, any noise levels produced by the devices under different circumstances during tooth extraction between the control and experimental groups. Conclusion: The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars. ? 2014. |
URI: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84943351798&doi=10.1016%2fj.jfma.2014.02.003&partnerID=40&md5=19f1713373e0a44b41d760949850ed1c https://scholars.lib.ntu.edu.tw/handle/123456789/572556 |
ISSN: | 0929-6646 | DOI: | 10.1016/j.jfma.2014.02.003 | SDG/Keyword: | adolescent; adult; Article; clinical article; controlled study; crossover procedure; dental device; dental drill; face edema; face pain; female; human; intermethod comparison; male; molar tooth; noise measurement; patient comfort; piezosurgery; piezotome; randomized controlled trial; tooth disease; tooth extraction; comparative study; molar tooth; noise; operation duration; pain measurement; Pain, Postoperative; piezosurgery; postoperative complication; procedures; self report; Taiwan; tooth extraction; Tooth, Impacted; young adult; Adolescent; Adult; Cross-Over Studies; Female; Humans; Male; Molar, Third; Noise; Operative Time; Pain Measurement; Pain, Postoperative; Piezosurgery; Postoperative Complications; Self Report; Taiwan; Tooth Extraction; Tooth, Impacted; Young Adult [SDGs]SDG3 |
Appears in Collections: | 臨床牙醫學研究所 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.