https://scholars.lib.ntu.edu.tw/handle/123456789/592783
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Siddique, Saulat | en_US |
dc.contributor.author | Hameed Khan, Aamir | en_US |
dc.contributor.author | Shahab, Hunaina | en_US |
dc.contributor.author | Zhang, Yu-Qing | en_US |
dc.contributor.author | Chin Tay, Jam | en_US |
dc.contributor.author | Buranakitjaroen, Peera | en_US |
dc.contributor.author | Turana, Yuda | en_US |
dc.contributor.author | Verma, Narsingh | en_US |
dc.contributor.author | Chen, Chen-Huan | en_US |
dc.contributor.author | Cheng, Hao-Min | en_US |
dc.contributor.author | TZUNG-DAU WANG | en_US |
dc.contributor.author | Van Minh, Huynh | en_US |
dc.contributor.author | Chia, Yook-Chin | en_US |
dc.contributor.author | Kario, Kazuomi | en_US |
dc.date.accessioned | 2022-01-21T05:38:10Z | - |
dc.date.available | 2022-01-21T05:38:10Z | - |
dc.date.issued | 2021-03 | - |
dc.identifier.issn | 1524-6175 | - |
dc.identifier.uri | https://scholars.lib.ntu.edu.tw/handle/123456789/592783 | - |
dc.description.abstract | The conventional auscultatory methods for measuring blood pressure have been used to screen, diagnose, and manage hypertension since long. However, these have been found to be prone to errors especially the white coat phenomena which cause falsely high blood pressure readings. The Mercury sphygmomanometer and the Aneroid variety are no longer recommended by WHO for varying reasons. The Oscillometric devices are now recommended with preference for the Automated Office Blood Pressure measurement device which was found to have readings nearest to the Awake Ambulatory Blood Pressure readings. The downside for this device is the cost barrier. The alternative is to use the simple oscillometric device, which is much cheaper, with the rest and isolation criteria of the SPRINT study. This too may be difficult due to space constraints and the post-clinic blood measurement is a new concept worth further exploration. | en_US |
dc.language.iso | en | en_US |
dc.publisher | WILEY | en_US |
dc.relation.ispartof | Journal of clinical hypertension (Greenwich, Conn.) | en_US |
dc.subject | AOBP; clinic BP; office BP; oscillometric devices | en_US |
dc.title | Office blood pressure measurement: A comprehensive review | en_US |
dc.type | journal article | en |
dc.type | review | en_US |
dc.identifier.doi | 10.1111/jch.14169 | - |
dc.identifier.pmid | 33420745 | - |
dc.identifier.scopus | 2-s2.0-85099238309 | - |
dc.identifier.isi | WOS:000605932800001 | - |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/85099238309 | - |
dc.relation.pages | 440 | en_US |
dc.relation.journalvolume | 23 | en_US |
dc.relation.journalissue | 3 | en_US |
dc.relation.pageend | 449 | en_US |
item.openairetype | journal article | - |
item.openairetype | review | - |
item.fulltext | no fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Internal Medicine | - |
crisitem.author.dept | Cardiovascular Center | - |
crisitem.author.orcid | 0000-0002-7180-3607 | - |
crisitem.author.parentorg | College of Medicine | - |
crisitem.author.parentorg | National Taiwan University Hospital | - |
顯示於: | 醫學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。